Simultaneous estimation and forced degradation studies of amlodipine besylate and indapamide in tablet dosage form by RP-HPLC method
G Rashmita, Vasanth P. M, Tippani Ramesh, Manikandan Ramesh
Abstract
G Rashmita, Vasanth P. M, Tippani Ramesh, Manikandan Ramesh
Abstract
The method developed for simultaneous estimation of Amlodipine besylate and Indapamide by using RP-HPLC method is simple, accurate, selective and economic by using c8 column (BDS Hypersil, 100×4.6mm,5μ particle size). Sample was analysed using water which is adjusted with ortho phosphoric acid buffer (OPA) to pH 3: Methanol in the ratio 600:400 as a mobile phase at a flow rate of 1ml\min. Detection was performed with PDA detector at 248nm. The retention time of Indapamide and Amlodipine besylate is 1.45 & 3.30 respectively. The correlation coefficient R2 value is found to be 0.999 for Amlodipine besylate and 0.999 for Indapamide. The LOD and LOQ values for Amlodipine besylate was found to be 0.00015 and 0.0005.The LOD and LOQ values for Indapamide was found to be 0.00028 and 0.00095 respectively. The proposed method was validated as per ICH guidelines with parameters like linearity, accuracy, Interday and precision, LOD, LOQ, robustness.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The method developed for simultaneous estimation of Amlodipine besylate and Indapamide by using RP-HPLC method is simple, accurate, selective and economic by using c8 column (BDS Hypersil, 100×4.6mm,5μ particle size). Sample was analysed using water which is adjusted with ortho phosphoric acid buffer (OPA) to pH 3: Methanol in the ratio 600:400 as a mobile phase at a flow rate of 1ml\min. Detection was performed with PDA detector at 248nm. The retention time of Indapamide and Amlodipine besylate is 1.45 & 3.30 respectively. The correlation coefficient R2 value is found to be 0.999 for Amlodipine besylate and 0.999 for Indapamide. The LOD and LOQ values for Amlodipine besylate was found to be 0.00015 and 0.0005.The LOD and LOQ values for Indapamide was found to be 0.00028 and 0.00095 respectively. The proposed method was validated as per ICH guidelines with parameters like linearity, accuracy, Interday and precision, LOD, LOQ, robustness.
Key concepts: Indapamide, Amlodipine, Chromatography, Chemistry, Phosphoric acid, High-performance liquid chromatography, Retention time, Pharmacology