2017Journal of Burn Care & ResearchOpen access

Burn Hand or Finger Goniometric Measurements

Reg Richard, Ingrid Parry, Alexis R. Santos‐Lozada, William S. Dewey

Open full text 25 citations

Abstract

Accurate assessment of hand function following a burn is important for patient impairment determination. Goniometric measurement of hand or finger range of motion (ROM) is typically done measuring individual finger joints with the adjacent joint in extension (isolated) or measuring the joints in a fist position (composite). The purpose of this study was to compare if the total flexion motion of the summed angles of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints in burned hands were equal when performed in an isolated vs a composite manner. Passive flexion ROM angles were collected prospectively and measured at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal with the adjacent joints extended to measure isolated angles and with the adjacent joints fully flexed for composite angles. Thumb joints were excluded. ROM for isolated and composite positions of eight fingers was compared individually and as an aggregate. Finger measurements from 145 adult patients were compared. The study population was predominately male (69%) with a mean age of 41 ± 16.6 years. Mean total burn size was 14.2 ± 13.2%. A total of 739 fingers contributed 2217 joint ROM comparisons. Aggregate analysis of isolated ROM was 235.5° ± 52.1° compared with composite ROM of 226.8° ± 53.2° (P < .0001). Individual fingers showed significant differences between the two measurement methods as well (P ≤ .0040). The methods used to measure hand or finger ROM profoundly influence how hand impairment is reported. Measurement of isolated joint angles results in greater ROM values compared with composite angles, which are often more relevant for functional hand positions. Therefore, composite angles are recommended.

Open-access reader

About this research paper

What this paper is about

Accurate assessment of hand function following a burn is important for patient impairment determination. Goniometric measurement of hand or finger range of motion (ROM) is typically done measuring individual finger joints with the adjacent joint in extension (isolated) or measuring the joints in a fist position (composite). The purpose of this study was to compare if the total flexion motion of the summed angles of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints in burned hands were equal when performed in an isolated vs a composite manner. Passive flexion ROM angles were collected prospectively and measured at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal with the adjacent joints extended to measure isolated angles and with the adjacent joints fully flexed for composite angles. Thumb joints were excluded. ROM for isolated and composite positions of eight fingers was compared individually and as an aggregate. Finger measurements from 145 adult patients were compared. The study population was predominately male (69%) with a mean age of 41 ± 16.6 years. Mean total burn size was 14.2 ± 13.2%. A total of 739 fingers contributed 2217 joint ROM comparisons. Aggregate analysis of isolated ROM was 235.5° ± 52.1° compared with composite ROM of 226.8° ± 53.2° (P < .0001). Individual fingers showed significant differences between the two measurement methods as well (P ≤ .0040). The methods used to measure hand or finger ROM profoundly influence how hand impairment is reported. Measurement of isolated joint angles results in greater ROM values compared with composite angles, which are often more relevant for functional hand positions. Therefore, composite angles are recommended.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Accurate assessment of hand function following a burn is important for patient impairment determination. Goniometric measurement of hand or finger range of motion (ROM) is typically done measuring individual finger joints with the adjacent joint in extension (isolated) or measuring the joints in a fist position (composite). The purpose of this study was to compare if the total flexion motion of the summed angles of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints in burned hands were equal when performed in an isolated vs a composite manner. Passive flexion ROM angles were collected prospectively and measured at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal with the adjacent joints extended to measure isolated angles and with the adjacent joints fully flexed for composite angles. Thumb joints were excluded. ROM for isolated and composite positions of eight fingers was compared individually and as an aggregate. Finger measurements from 145 adult patients were compared. The study population was predominately male (69%) with a mean age of 41 ± 16.6 years. Mean total burn size was 14.2 ± 13.2%. A total of 739 fingers contributed 2217 joint ROM comparisons. Aggregate analysis of isolated ROM was 235.5° ± 52.1° compared with composite ROM of 226.8° ± 53.2° (P < .0001). Individual fingers showed significant differences between the two measurement methods as well (P ≤ .0040). The methods used to measure hand or finger ROM profoundly influence how hand impairment is reported. Measurement of isolated joint angles results in greater ROM values compared with composite angles, which are often more relevant for functional hand positions. Therefore, composite angles are recommended.

Key concepts: Interphalangeal Joint, Finger joint, Medicine, Range of motion, Goniometer, Thumb, Metacarpophalangeal joint, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source