2017•Energy ProcediaOpen access

Modelling and Simulation of Concentrating Photovoltaic System with Earth Water Heat Exchanger Cooling

Sanjeev Jakhar, Manoj Kumar Soni, Nikhil Gakkhar

Open full text 26 citations

Abstract

In the present paper, a novel cooling system for concentrating photovoltaic (CPV) which is termed as earth water heat exchanger (EWHE) is modeled and simulated for local conditions of Pilani, Rajasthan. The CPV temperature and power output are obtained with respect to variation in mass flow rate of fluid and concentration ratio (CR). The simulation results shows that the maximum CPV temperature goes up to 416.36 °C at 3 Suns without any cooling, while with cooling it is reduced down to 85.28 °C for the mass flow rate of 0.022 kg/s. CPV temperature drop and power output increases with increasing in mass flow rate when it operated with EWHE in a closed loop. The mass flow rate of 0.022 kg/s is estimated as suitable flow rate as it may be used for the practical applications. It is also observed that with increase in mass flow rate the outlet temperature of CPV/T decreased.

Open-access reader

About this research paper

What this paper is about

In the present paper, a novel cooling system for concentrating photovoltaic (CPV) which is termed as earth water heat exchanger (EWHE) is modeled and simulated for local conditions of Pilani, Rajasthan. The CPV temperature and power output are obtained with respect to variation in mass flow rate of fluid and concentration ratio (CR). The simulation results shows that the maximum CPV temperature goes up to 416.36 °C at 3 Suns without any cooling, while with cooling it is reduced down to 85.28 °C for the mass flow rate of 0.022 kg/s. CPV temperature drop and power output increases with increasing in mass flow rate when it operated with EWHE in a closed loop. The mass flow rate of 0.022 kg/s is estimated as suitable flow rate as it may be used for the practical applications. It is also observed that with increase in mass flow rate the outlet temperature of CPV/T decreased.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the present paper, a novel cooling system for concentrating photovoltaic (CPV) which is termed as earth water heat exchanger (EWHE) is modeled and simulated for local conditions of Pilani, Rajasthan. The CPV temperature and power output are obtained with respect to variation in mass flow rate of fluid and concentration ratio (CR). The simulation results shows that the maximum CPV temperature goes up to 416.36 °C at 3 Suns without any cooling, while with cooling it is reduced down to 85.28 °C for the mass flow rate of 0.022 kg/s. CPV temperature drop and power output increases with increasing in mass flow rate when it operated with EWHE in a closed loop. The mass flow rate of 0.022 kg/s is estimated as suitable flow rate as it may be used for the practical applications. It is also observed that with increase in mass flow rate the outlet temperature of CPV/T decreased.

Key concepts: Mass flow rate, Volumetric flow rate, Heat exchanger, Mass flow, Water cooling, Mechanics, Materials science, Photovoltaic system

Related papers

Back to paper searchBrowse research topicsOriginal source
Modelling and Simulation of Concentrating Photovoltaic System with Earth Water Heat Exchanger Cooling — Research Paper | ScholarLens