CATASTROPHIC FAILURE ASSOCIATED WITH THE WAGNER HIP RESURFACING PROSTHESIS AND THE IMPACT ON SUBSEQUENT REVISION SURGERY
R.U. Ashford, Antonio Frasquet-Garcia, Piet de Boer, Pat Campbell
Abstract
R.U. Ashford, Antonio Frasquet-Garcia, Piet de Boer, Pat Campbell
Abstract
Hip resurfacing is a procedure designed to conserve bone stock in the younger patient and facilitate revision to a total hip arthroplasty if the need arises. The Wagner Hip Resurfacing (WHR) was a metal-on- poly implant introduced in 1978. The notes and radiographs of 16 patients who underwent 19 WHR procedures performed by a single surgeon between 1980 and 1984 were reviewed. The mean age at primary surgery was 54 (range 41–68). 16 of the WHRs required revision at a mean time of 45 months (range 1–144 months). 3 WHR had not been revised: one is functioning at 22 years, one functioning well 20 years after implantation when the patient died and 1 non-functional 9 years after implantation due to femoral head reabsorption. The reason for revision was femoral neck fracture (3), femoral head collapse / avascular necrosis or loosening (8), acetabular loosening (5). Subsequent problems with the revision were noted in 6 patients (2 dislocations, 2 infections, 1 acetabular loosening and 1 femoral loosening). 3 patients ended with a Girdlestone excision arthroplasty and 2 required re-revision. Hip resurfacing is designed as a conservative option for the young arthritic hip. This prosthesis not only failed catastrophically at an early stage but had a major subsequent impact on revision surgery and complications associated with it.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Hip resurfacing is a procedure designed to conserve bone stock in the younger patient and facilitate revision to a total hip arthroplasty if the need arises. The Wagner Hip Resurfacing (WHR) was a metal-on- poly implant introduced in 1978. The notes and radiographs of 16 patients who underwent 19 WHR procedures performed by a single surgeon between 1980 and 1984 were reviewed. The mean age at primary surgery was 54 (range 41–68). 16 of the WHRs required revision at a mean time of 45 months (range 1–144 months). 3 WHR had not been revised: one is functioning at 22 years, one functioning well 20 years after implantation when the patient died and 1 non-functional 9 years after implantation due to femoral head reabsorption. The reason for revision was femoral neck fracture (3), femoral head collapse / avascular necrosis or loosening (8), acetabular loosening (5). Subsequent problems with the revision were noted in 6 patients (2 dislocations, 2 infections, 1 acetabular loosening and 1 femoral loosening). 3 patients ended with a Girdlestone excision arthroplasty and 2 required re-revision. Hip resurfacing is designed as a conservative option for the young arthritic hip. This prosthesis not only failed catastrophically at an early stage but had a major subsequent impact on revision surgery and complications associated with it.
Key concepts: Medicine, Surgery, Hip resurfacing, Femoral head, Avascular necrosis, Prosthesis, Femoral neck, Implant