DOSIMETRIC QUANTITY SYSTEM FOR ELECTROMAGNETIC FIELDS BIOEFFECTS

Dragoș Păsculescu, Remus Dobra, M. Ayaz Ahmad

Open publisher page 2 citations

Abstract

Dosimetric evaluation system used is able to determine the distribution of SAR (Specific Absorption Rate) inside a phantom model that complies with European and USA standards (EN 50361, IEEE 1528). It consists of a robot, an electric field probe calibrated for use in liquids, a ghost twin ghost elliptical flat fluid simulation of human tissue, a gripping device DUT (device under test) and software Open SAR. Specific Absorption Rate (or SAR) is a measure of how transmitted RF energy is absorbed by human tissue. SAR is a function of the electrical conductivity, the induced E-field from the radiated energy (measured in Volts/meter) and the mass density of the tissue.Due to the high sensitivity of the probe, its output voltage is measured without amplification. Electric field probe corresponds to the recommendations of CENELEC (European Committee for the Coordination of Electrical Standards) and IEEE (Committee of Electrical and Electronic Engineers in the field) for measuring electromagnetic fields of mobile phones, base stations and radiating devices. DUT latch is constructed of a material with low loss and low permittivity. It allows moving the axes Ox, Oy, Oz or rotation around phantom ear for precise positioning of the DUT. With the software robot motion control Open SAR, local SAR values are determined and calculated SAR values averaged over 10 grams and 1 gram of tissue.

About this research paper

What this paper is about

Dosimetric evaluation system used is able to determine the distribution of SAR (Specific Absorption Rate) inside a phantom model that complies with European and USA standards (EN 50361, IEEE 1528). It consists of a robot, an electric field probe calibrated for use in liquids, a ghost twin ghost elliptical flat fluid simulation of human tissue, a gripping device DUT (device under test) and software Open SAR. Specific Absorption Rate (or SAR) is a measure of how transmitted RF energy is absorbed by human tissue. SAR is a function of the electrical conductivity, the induced E-field from the radiated energy (measured in Volts/meter) and the mass density of the tissue.Due to the high sensitivity of the probe, its output voltage is measured without amplification. Electric field probe corresponds to the recommendations of CENELEC (European Committee for the Coordination of Electrical Standards) and IEEE (Committee of Electrical and Electronic Engineers in the field) for measuring electromagnetic fields of mobile phones, base stations and radiating devices. DUT latch is constructed of a material with low loss and low permittivity. It allows moving the axes Ox, Oy, Oz or rotation around phantom ear for precise positioning of the DUT. With the software robot motion control Open SAR, local SAR values are determined and calculated SAR values averaged over 10 grams and 1 gram of tissue.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Dosimetric evaluation system used is able to determine the distribution of SAR (Specific Absorption Rate) inside a phantom model that complies with European and USA standards (EN 50361, IEEE 1528). It consists of a robot, an electric field probe calibrated for use in liquids, a ghost twin ghost elliptical flat fluid simulation of human tissue, a gripping device DUT (device under test) and software Open SAR. Specific Absorption Rate (or SAR) is a measure of how transmitted RF energy is absorbed by human tissue. SAR is a function of the electrical conductivity, the induced E-field from the radiated energy (measured in Volts/meter) and the mass density of the tissue.Due to the high sensitivity of the probe, its output voltage is measured without amplification. Electric field probe corresponds to the recommendations of CENELEC (European Committee for the Coordination of Electrical Standards) and IEEE (Committee of Electrical and Electronic Engineers in the field) for measuring electromagnetic fields of mobile phones, base stations and radiating devices. DUT latch is constructed of a material with low loss and low permittivity. It allows moving the axes Ox, Oy, Oz or rotation around phantom ear for precise positioning of the DUT. With the software robot motion control Open SAR, local SAR values are determined and calculated SAR values averaged over 10 grams and 1 gram of tissue.

Key concepts: Specific absorption rate, Imaging phantom, Sensitivity (control systems), Absorption (acoustics), Electric field, Acoustics, Electromagnetic field, Metre

Related papers

Back to paper searchBrowse research topicsOriginal source
DOSIMETRIC QUANTITY SYSTEM FOR ELECTROMAGNETIC FIELDS BIOEFFECTS — Research Paper | ScholarLens