2017•Acta ChromatographicaOpen access

A validated HPLC–MS/MS method for the quantification of supinoxin in rat plasma and its application to pharmacokinetic study

Jong‐Woo Jeong, Yun-Hwan Seol, Hun-Chan Hyun, Hyerim Kim, Jong-Hwa Lee, Young‐Dae Gong, Nam Sook Kang, Tae‐Sung Koo

Open full text 3 citations

Abstract

A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of an anticancer drug, supinoxin (RX-5902), in rat plasma. Following precipitation pretreatment using 0.1% formic acid in acetonitrile, separation was performed using a reverse phase liquid chromatography column packed with C18 (3.5 μm, 2.1 × 50 mm) along with a mobile phase of 0.1% formic acid in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.3 mL min−1. Detection was achieved using MS/MS by multiple reaction monitoring via an electrospray ionization source at mass/charge transitions of m/z 442.30 → 223.30 for supinoxin and m/z 430.08 → 223.20 for the internal standard DGG-200064. This method demonstrated a linear standard curve (r = 0.9980) over a supinoxin concentration range of 0.0005–1 μg mL−1, as well as intra- and inter-assay precisions below 7.08% and 13.74%, respectively, and an accuracy of 1.15–4.50%. The matrix effect, recovery, and process efficiency were 93.63%, 99.70%, and 93.33%, respectively. Thus, a sensitive and reliable LC–MS/MS method was developed and validated for the quantification of supinoxin in rat plasma. This method was successfully applied to the evaluation of pharmacokinetic studies after single intravenous and oral administration of 1 mg kg−1 supinoxin in rats.

About this research paper

What this paper is about

A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of an anticancer drug, supinoxin (RX-5902), in rat plasma. Following precipitation pretreatment using 0.1% formic acid in acetonitrile, separation was performed using a reverse phase liquid chromatography column packed with C18 (3.5 μm, 2.1 × 50 mm) along with a mobile phase of 0.1% formic acid in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.3 mL min−1. Detection was achieved using MS/MS by multiple reaction monitoring via an electrospray ionization source at mass/charge transitions of m/z 442.30 → 223.30 for supinoxin and m/z 430.08 → 223.20 for the internal standard DGG-200064. This method demonstrated a linear standard curve (r = 0.9980) over a supinoxin concentration range of 0.0005–1 μg mL−1, as well as intra- and inter-assay precisions below 7.08% and 13.74%, respectively, and an accuracy of 1.15–4.50%. The matrix effect, recovery, and process efficiency were 93.63%, 99.70%, and 93.33%, respectively. Thus, a sensitive and reliable LC–MS/MS method was developed and validated for the quantification of supinoxin in rat plasma. This method was successfully applied to the evaluation of pharmacokinetic studies after single intravenous and oral administration of 1 mg kg−1 supinoxin in rats.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of an anticancer drug, supinoxin (RX-5902), in rat plasma. Following precipitation pretreatment using 0.1% formic acid in acetonitrile, separation was performed using a reverse phase liquid chromatography column packed with C18 (3.5 μm, 2.1 × 50 mm) along with a mobile phase of 0.1% formic acid in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.3 mL min−1. Detection was achieved using MS/MS by multiple reaction monitoring via an electrospray ionization source at mass/charge transitions of m/z 442.30 → 223.30 for supinoxin and m/z 430.08 → 223.20 for the internal standard DGG-200064. This method demonstrated a linear standard curve (r = 0.9980) over a supinoxin concentration range of 0.0005–1 μg mL−1, as well as intra- and inter-assay precisions below 7.08% and 13.74%, respectively, and an accuracy of 1.15–4.50%. The matrix effect, recovery, and process efficiency were 93.63%, 99.70%, and 93.33%, respectively. Thus, a sensitive and reliable LC–MS/MS method was developed and validated for the quantification of supinoxin in rat plasma. This method was successfully applied to the evaluation of pharmacokinetic studies after single intravenous and oral administration of 1 mg kg−1 supinoxin in rats.

Key concepts: Chemistry, Chromatography, Formic acid, Protein precipitation, Electrospray ionization, Pharmacokinetics, Selected reaction monitoring, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
A validated HPLC–MS/MS method for the quantification of supinoxin in rat plasma and its application to pharmacokinetic study — Research Paper | ScholarLens