EVALUATION OF INTERNAL ADAPTATION OF FULL CONTOUR ZIRCONIA CROWNS VERSUS VENEERED ZIRCONIA CROWNS – IN VITRO STUDY
Abdulsattar Hasan Al-Baadani, Rana Sherief, Ashraf Kheireldean
Abstract
Open-access reader
Abdulsattar Hasan Al-Baadani, Rana Sherief, Ashraf Kheireldean
Abstract
Open-access reader
Purpose: To evaluate the internal adaptation of full contour zirconia crowns to veneered zirconia with two different finish line designs (shoulder and deep chamfer). Materials and Methods: Twenty four dies were received twelve full contour zirconia crowns (Prettau) and twelve veneered zirconia crowns (ICE Zirconia). Each group will be subdivided into two equally subgroups: with Shoulder finish line and with Deep chamfer finish line. Measurements of internal fitness were recorded Results: The lowest overall mean value of internal adaptation was recorded with Ice zirconia crowns with deep chamfer finish line design (74.6µm ± 19.14), then with shoulder finish line design (93.40 µm ± 9.99), followed by Prettau zirconia crowns with deep chamfer finish line design (157µm ± 27.25) and finally Prettau zirconia crowns with shoulder finish line design (181µm ± 24.86). Conclusions: The ice zirconia crowns recorded better overall internal adaptation values than Prettau crowns with both finish line designs.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: To evaluate the internal adaptation of full contour zirconia crowns to veneered zirconia with two different finish line designs (shoulder and deep chamfer). Materials and Methods: Twenty four dies were received twelve full contour zirconia crowns (Prettau) and twelve veneered zirconia crowns (ICE Zirconia). Each group will be subdivided into two equally subgroups: with Shoulder finish line and with Deep chamfer finish line. Measurements of internal fitness were recorded Results: The lowest overall mean value of internal adaptation was recorded with Ice zirconia crowns with deep chamfer finish line design (74.6µm ± 19.14), then with shoulder finish line design (93.40 µm ± 9.99), followed by Prettau zirconia crowns with deep chamfer finish line design (157µm ± 27.25) and finally Prettau zirconia crowns with shoulder finish line design (181µm ± 24.86). Conclusions: The ice zirconia crowns recorded better overall internal adaptation values than Prettau crowns with both finish line designs.
Key concepts: Chamfer (geometry), Cubic zirconia, Finish line, Materials science, Orthodontics, Composite material, Medicine, Geology