2017PLoS ONEOpen access

Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children

Li‐Wen Lee, Yu-San Liao, Hsueh-Kuan Lu, Pei-Lin Hsiao, Yu-Yawn Chen, Chi Ching-Chi, Kuen-Chang Hsieh

Open full text 79 citations

Abstract

BACKGROUND: Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. METHODS: Children aged 7-12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. RESULTS: There were strong linear correlations in body composition measurements between the BIA8SF and DXA and between the BIA8MF and DXA. Both BIAs underestimated fat mass (FM) and percentage body fat (%BF) relative to DXA in both genders The degree of agreement in lean body mass (LBM), FM, and %BF estimates was higher between BIA8MF and DXA than between BIA8SF and DXA. The Lin's concordance correlation coefficient (ρc) for LBM8MF met the criteria of substantial to perfect agreement whereas the ρc for FM8MF met the criteria of fair to substantial agreement. Bland-Altman analysis showed a clinically acceptable agreement between LBM measures by BIA8MF and DXA. The limit of agreement in %BF estimation by BIA and DXA were wide and the errors were clinically important. For the estimation of ALM, BIA8SF and BIA8MF both provided poor accuracy. CONCLUSIONS: For all children, LBM measures were precise and accurate using the BIA8MF whereas clinically significant errors occurred in FM and %BF estimates. Both BIAs underestimated FM and %BF in children. Thus, the body composition results obtained using the inbuilt equations of the BIA8SF and BIA8MF should be interpreted with caution, and high quality validation studies for specific subgroups of children are required prior to field research.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. METHODS: Children aged 7-12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. RESULTS: There were strong linear correlations in body composition measurements between the BIA8SF and DXA and between the BIA8MF and DXA. Both BIAs underestimated fat mass (FM) and percentage body fat (%BF) relative to DXA in both genders The degree of agreement in lean body mass (LBM), FM, and %BF estimates was higher between BIA8MF and DXA than between BIA8SF and DXA. The Lin's concordance correlation coefficient (ρc) for LBM8MF met the criteria of substantial to perfect agreement whereas the ρc for FM8MF met the criteria of fair to substantial agreement. Bland-Altman analysis showed a clinically acceptable agreement between LBM measures by BIA8MF and DXA. The limit of agreement in %BF estimation by BIA and DXA were wide and the errors were clinically important. For the estimation of ALM, BIA8SF and BIA8MF both provided poor accuracy. CONCLUSIONS: For all children, LBM measures were precise and accurate using the BIA8MF whereas clinically significant errors occurred in FM and %BF estimates. Both BIAs underestimated FM and %BF in children. Thus, the body composition results obtained using the inbuilt equations of the BIA8SF and BIA8MF should be interpreted with caution, and high quality validation studies for specific subgroups of children are required prior to field research.

Why it matters

OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. METHODS: Children aged 7-12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. RESULTS: There were strong linear correlations in body composition measurements between the BIA8SF and DXA and between the BIA8MF and DXA. Both BIAs underestimated fat mass (FM) and percentage body fat (%BF) relative to DXA in both genders The degree of agreement in lean body mass (LBM), FM, and %BF estimates was higher between BIA8MF and DXA than between BIA8SF and DXA. The Lin's concordance correlation coefficient (ρc) for LBM8MF met the criteria of substantial to perfect agreement whereas the ρc for FM8MF met the criteria of fair to substantial agreement. Bland-Altman analysis showed a clinically acceptable agreement between LBM measures by BIA8MF and DXA. The limit of agreement in %BF estimation by BIA and DXA were wide and the errors were clinically important. For the estimation of ALM, BIA8SF and BIA8MF both provided poor accuracy. CONCLUSIONS: For all children, LBM measures were precise and accurate using the BIA8MF whereas clinically significant errors occurred in FM and %BF estimates. Both BIAs underestimated FM and %BF in children. Thus, the body composition results obtained using the inbuilt equations of the BIA8SF and BIA8MF should be interpreted with caution, and high quality validation studies for specific subgroups of children are required prior to field research.

Key concepts: Bioelectrical impedance analysis, Limits of agreement, Medicine, Bland–Altman plot, Lean body mass, Dual-energy X-ray absorptiometry, Concordance, Fat free mass

Related papers

Back to paper searchBrowse research topicsOriginal source
Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children — Research Paper | ScholarLens