2010•Der pharma chemicaRequires access

Simultaneous Spectrophotometric Estimation of Diacerein and Aceclofenac in tablet dosage form

Sohan S. Chitlange, Ganesh R. Pawbake, Amir I. Mulla, Sagar Baliram Wankhede

Open publisher page 6 citations

Abstract

Three UV spectrophotometric methods for the simultaneous determination of Diacerein (DIA), and aceclofenac (ACE) in tablets were developed in the present work. Method I is simultaneous equation method, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method II involves multicomponent mode of analysis, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method III is area under curve method, wavelength range selected are 263.5-253.5 nm for Diacerein and 279-269 nm for aceclofenac respectively. All the methods were found linear between 2-14 μg/ml for Diacerein and 4-28 μg/ml for aceclofenac. The accuracy and precision of the methods were determined and validated stastically which showed no significant difference between the results obtained by the three methods. The proposed methods are simple, accurate and can be used for its intended purpose.

About this research paper

What this paper is about

Three UV spectrophotometric methods for the simultaneous determination of Diacerein (DIA), and aceclofenac (ACE) in tablets were developed in the present work. Method I is simultaneous equation method, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method II involves multicomponent mode of analysis, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method III is area under curve method, wavelength range selected are 263.5-253.5 nm for Diacerein and 279-269 nm for aceclofenac respectively. All the methods were found linear between 2-14 μg/ml for Diacerein and 4-28 μg/ml for aceclofenac. The accuracy and precision of the methods were determined and validated stastically which showed no significant difference between the results obtained by the three methods. The proposed methods are simple, accurate and can be used for its intended purpose.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three UV spectrophotometric methods for the simultaneous determination of Diacerein (DIA), and aceclofenac (ACE) in tablets were developed in the present work. Method I is simultaneous equation method, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method II involves multicomponent mode of analysis, wavelength selected are 258.5 nm (λmax of Diacerein) and 274 nm (λmax of aceclofenac). Method III is area under curve method, wavelength range selected are 263.5-253.5 nm for Diacerein and 279-269 nm for aceclofenac respectively. All the methods were found linear between 2-14 μg/ml for Diacerein and 4-28 μg/ml for aceclofenac. The accuracy and precision of the methods were determined and validated stastically which showed no significant difference between the results obtained by the three methods. The proposed methods are simple, accurate and can be used for its intended purpose.

Key concepts: Aceclofenac, Mathematics, Chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Spectrophotometric Estimation of Diacerein and Aceclofenac in tablet dosage form — Research Paper | ScholarLens