2007•ROSA POpen access

Breath-Collection Device for Delayed Breath-Alcohol Analysis

Kurt M. Dubowski, University of Oklahoma: Department of Medicine & Toxicology Laboratories

Open full text 0 citations

Abstract

The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for later laboratory analysis for independent verification of evidential breath-alcohol tests for traffic law enforcement purposes, and research uses. The work involved development of a BCD consisting of a molecular sieve 13X column as the alcohol sorbent for 250 ml. samples, development of a method of analysis for the stored alcohol, and both in-vitro and in-vivo evaluation of the delayed analysis system. Alcohol analysis was performed by automated gas chromatographic headspace analysis on the-aqueous alcohol eluate from the molecular sieve. Evaluations included studies with precision-simulator effluents which showed essentially complete recovery of the alcohol, and studies with 32 alcohol-consuming human subjects. Results of direct breath-alcohol analysis with a Gas Chromatographic Intoximeter and of delayed gas chromatographic analyses after intervening alcohol sorption on molecular sieve 13X, on 369 series-sampled split breath specimens, were essentially identical with a mean difference of 0.00032 g/210 L. Complete alcohol retention for at least 11 months was shown to be feasible. /Abstract from report summary page/

About this research paper

What this paper is about

The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for later laboratory analysis for independent verification of evidential breath-alcohol tests for traffic law enforcement purposes, and research uses. The work involved development of a BCD consisting of a molecular sieve 13X column as the alcohol sorbent for 250 ml. samples, development of a method of analysis for the stored alcohol, and both in-vitro and in-vivo evaluation of the delayed analysis system. Alcohol analysis was performed by automated gas chromatographic headspace analysis on the-aqueous alcohol eluate from the molecular sieve. Evaluations included studies with precision-simulator effluents which showed essentially complete recovery of the alcohol, and studies with 32 alcohol-consuming human subjects. Results of direct breath-alcohol analysis with a Gas Chromatographic Intoximeter and of delayed gas chromatographic analyses after intervening alcohol sorption on molecular sieve 13X, on 369 series-sampled split breath specimens, were essentially identical with a mean difference of 0.00032 g/210 L. Complete alcohol retention for at least 11 months was shown to be feasible. /Abstract from report summary page/

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for later laboratory analysis for independent verification of evidential breath-alcohol tests for traffic law enforcement purposes, and research uses. The work involved development of a BCD consisting of a molecular sieve 13X column as the alcohol sorbent for 250 ml. samples, development of a method of analysis for the stored alcohol, and both in-vitro and in-vivo evaluation of the delayed analysis system. Alcohol analysis was performed by automated gas chromatographic headspace analysis on the-aqueous alcohol eluate from the molecular sieve. Evaluations included studies with precision-simulator effluents which showed essentially complete recovery of the alcohol, and studies with 32 alcohol-consuming human subjects. Results of direct breath-alcohol analysis with a Gas Chromatographic Intoximeter and of delayed gas chromatographic analyses after intervening alcohol sorption on molecular sieve 13X, on 369 series-sampled split breath specimens, were essentially identical with a mean difference of 0.00032 g/210 L. Complete alcohol retention for at least 11 months was shown to be feasible. /Abstract from report summary page/

Key concepts: Breath gas analysis, Medicine, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Breath-Collection Device for Delayed Breath-Alcohol Analysis — Research Paper | ScholarLens