2011•Der pharma chemicaRequires access

Stability indicating simultaneous estimation of assay method for naproxen and esomeprazole in pharmaceutical formulations by RP-HPLC

Palavai Sripal Reddy, Shakil S. Sait, Gururaj Vasudevmurthy, Badri Vishwanath, Vure Prasad, S. Jayapal Reddy

Open publisher page 29 citations

Abstract

Naproxen is a Non steroidal simultaneous anti inflammatory drug (NSAID) used in the treatment of pain or inflammation caused by conditions such as arthritis, ankylosing spondylitis, tendinitis, bursitis, gout, or menstrual cramps. Esomeprazole is used to treat gastro esophageal reflux disease. A simple, precise cost effective and stability indicating RP-HPLC method has been developed and validated for the determination of both Naproxen and Esomeprazole in pharmaceutical compositions. Separation of Naproxen and Esomeprazole from its potentional degradants were achieved within a shorter run time with required resolution, accuracy and precision thus enabling the utility of the method for routine analysis. The chromatographic separation was achieved on a Xterra RP-18 column (150 × 4.6 mm, 5μ) using a mobile phase consisting buffer prepared with 0.005 mole of sodium perchlorate, 5 mL N-butyl amine in milli-Q grade water with a pH of 8.7 which is mixed with Acetonitrile and Methanol at a flow rate of 1.5 mL per minute. Wavelength chosen for detection is 305 nm. The retention times of Naproxen and Esomeprazole peaks are around 3 and 6 minute respectively. The method was found to be linear over the range of 100.28 to 902.520 μg per mL for Naproxen and 9.6 to 45.6 μg per mL for Esomeprazole. The proposed method is validated as per the ICH and USP guidelines.

About this research paper

What this paper is about

Naproxen is a Non steroidal simultaneous anti inflammatory drug (NSAID) used in the treatment of pain or inflammation caused by conditions such as arthritis, ankylosing spondylitis, tendinitis, bursitis, gout, or menstrual cramps. Esomeprazole is used to treat gastro esophageal reflux disease. A simple, precise cost effective and stability indicating RP-HPLC method has been developed and validated for the determination of both Naproxen and Esomeprazole in pharmaceutical compositions. Separation of Naproxen and Esomeprazole from its potentional degradants were achieved within a shorter run time with required resolution, accuracy and precision thus enabling the utility of the method for routine analysis. The chromatographic separation was achieved on a Xterra RP-18 column (150 × 4.6 mm, 5μ) using a mobile phase consisting buffer prepared with 0.005 mole of sodium perchlorate, 5 mL N-butyl amine in milli-Q grade water with a pH of 8.7 which is mixed with Acetonitrile and Methanol at a flow rate of 1.5 mL per minute. Wavelength chosen for detection is 305 nm. The retention times of Naproxen and Esomeprazole peaks are around 3 and 6 minute respectively. The method was found to be linear over the range of 100.28 to 902.520 μg per mL for Naproxen and 9.6 to 45.6 μg per mL for Esomeprazole. The proposed method is validated as per the ICH and USP guidelines.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Naproxen is a Non steroidal simultaneous anti inflammatory drug (NSAID) used in the treatment of pain or inflammation caused by conditions such as arthritis, ankylosing spondylitis, tendinitis, bursitis, gout, or menstrual cramps. Esomeprazole is used to treat gastro esophageal reflux disease. A simple, precise cost effective and stability indicating RP-HPLC method has been developed and validated for the determination of both Naproxen and Esomeprazole in pharmaceutical compositions. Separation of Naproxen and Esomeprazole from its potentional degradants were achieved within a shorter run time with required resolution, accuracy and precision thus enabling the utility of the method for routine analysis. The chromatographic separation was achieved on a Xterra RP-18 column (150 × 4.6 mm, 5μ) using a mobile phase consisting buffer prepared with 0.005 mole of sodium perchlorate, 5 mL N-butyl amine in milli-Q grade water with a pH of 8.7 which is mixed with Acetonitrile and Methanol at a flow rate of 1.5 mL per minute. Wavelength chosen for detection is 305 nm. The retention times of Naproxen and Esomeprazole peaks are around 3 and 6 minute respectively. The method was found to be linear over the range of 100.28 to 902.520 μg per mL for Naproxen and 9.6 to 45.6 μg per mL for Esomeprazole. The proposed method is validated as per the ICH and USP guidelines.

Key concepts: Esomeprazole, Naproxen, Chromatography, Chemistry, Piroxicam, High-performance liquid chromatography, Medicine, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Stability indicating simultaneous estimation of assay method for naproxen and esomeprazole in pharmaceutical formulations by RP-HPLC — Research Paper | ScholarLens