2017Scandinavian Journal of Infectious DiseasesOpen access

Accurate and fast urinalysis in febrile patients by flow cytometry

Foppie J. de Boer, Elske Gieteling, Heidi van Egmond-Kreileman, Bijan Moshaver, Sjef J. C. M. van de Leur, Coen A. Stegeman, Paul H P Groeneveld

Open full text 16 citations

Abstract

Background: The urine culture is worldwide accepted as the gold standard in diagnosing urinary tract infections, but is time consuming and costly, other methods are fast but moderately reliable. We investigated whether counting the number of bacteria by flow cytometry could be a fast and accurate method to analyze urine samples in febrile patients at the emergency department (ED).Methods: Urine samples were obtained from 140 febrile patients at the ED. Urinalysis was performed according to standard procedures. Flow cytometric analysis for bacteria was performed with the Accuri C6 flow cytometer. Diagnostic values were determined at various cut-off points by using urine culture as the gold standard.Results: The highest diagnostic accuracy of urinalysis of bacteria was obtained with flow cytometric analysis (AUC of 0.96). The best cut-off value for bacteria counted by flow cytometry based on the ROC-curve was 3.72 × 106 bacteria/mL, this resulted in a sensitivity of 94.7% and a specificity of 88.2%.Conclusions: Counting bacteria by flow cytometry has the highest diagnostic accuracy and is superior to other methods in urinalysis in febrile patients in the ED when using urine culture as the gold standard.

About this research paper

What this paper is about

Background: The urine culture is worldwide accepted as the gold standard in diagnosing urinary tract infections, but is time consuming and costly, other methods are fast but moderately reliable. We investigated whether counting the number of bacteria by flow cytometry could be a fast and accurate method to analyze urine samples in febrile patients at the emergency department (ED).Methods: Urine samples were obtained from 140 febrile patients at the ED. Urinalysis was performed according to standard procedures. Flow cytometric analysis for bacteria was performed with the Accuri C6 flow cytometer. Diagnostic values were determined at various cut-off points by using urine culture as the gold standard.Results: The highest diagnostic accuracy of urinalysis of bacteria was obtained with flow cytometric analysis (AUC of 0.96). The best cut-off value for bacteria counted by flow cytometry based on the ROC-curve was 3.72 × 106 bacteria/mL, this resulted in a sensitivity of 94.7% and a specificity of 88.2%.Conclusions: Counting bacteria by flow cytometry has the highest diagnostic accuracy and is superior to other methods in urinalysis in febrile patients in the ED when using urine culture as the gold standard.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: The urine culture is worldwide accepted as the gold standard in diagnosing urinary tract infections, but is time consuming and costly, other methods are fast but moderately reliable. We investigated whether counting the number of bacteria by flow cytometry could be a fast and accurate method to analyze urine samples in febrile patients at the emergency department (ED).Methods: Urine samples were obtained from 140 febrile patients at the ED. Urinalysis was performed according to standard procedures. Flow cytometric analysis for bacteria was performed with the Accuri C6 flow cytometer. Diagnostic values were determined at various cut-off points by using urine culture as the gold standard.Results: The highest diagnostic accuracy of urinalysis of bacteria was obtained with flow cytometric analysis (AUC of 0.96). The best cut-off value for bacteria counted by flow cytometry based on the ROC-curve was 3.72 × 106 bacteria/mL, this resulted in a sensitivity of 94.7% and a specificity of 88.2%.Conclusions: Counting bacteria by flow cytometry has the highest diagnostic accuracy and is superior to other methods in urinalysis in febrile patients in the ED when using urine culture as the gold standard.

Key concepts: Urinalysis, Gold standard (test), Urine, Medicine, Flow cytometry, Urinary system, Microbiological culture, Cytometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Accurate and fast urinalysis in febrile patients by flow cytometry — Research Paper | ScholarLens