2017•PLoS ONEOpen access

A Device-Independent Evaluation of Carbonyl Emissions from Heated Electronic Cigarette Solvents

Ping Wang, Wenhao Chen, Jiawen Liao, Toshiki Matsuo, Kazuhide Ito, Jefferson R Fowles, Dennis J. Shusterman, Mark J. Mendell, Kazukiyo Kumagai

Open full text 137 citations

Abstract

OBJECTIVES: To investigate how the two main electronic (e-) cigarette solvents-propylene glycol (PG) and glycerol (GL)-modulate the formation of toxic volatile carbonyl compounds under precisely controlled temperatures in the absence of nicotine and flavor additives. METHODS: PG, GL, PG:GL = 1:1 (wt/wt) mixture, and two commercial e-cigarette liquids were vaporized in a stainless steel, tubular reactor in flowing air ranging up to 318°C to simulate e-cigarette vaping. Aerosols were collected and analyzed to quantify the amount of volatile carbonyls produced with each of the five e-liquids. RESULTS: Significant amounts of formaldehyde and acetaldehyde were detected at reactor temperatures ≥215°C for both PG and GL. Acrolein was observed only in e-liquids containing GL when reactor temperatures exceeded 270°C. At 318°C, 2.03±0.80 μg of formaldehyde, 2.35±0.87 μg of acetaldehyde, and a trace amount of acetone were generated per milligram of PG; at the same temperature, 21.1±3.80 μg of formaldehyde, 2.40±0.99 μg of acetaldehyde, and 0.80±0.50 μg of acrolein were detected per milligram of GL. CONCLUSIONS: We developed a device-independent test method to investigate carbonyl emissions from different e-cigarette liquids under precisely controlled temperatures. PG and GL were identified to be the main sources of toxic carbonyl compounds from e-cigarette use. GL produced much more formaldehyde than PG. Besides formaldehyde and acetaldehyde, measurable amounts of acrolein were also detected at ≥270°C but only when GL was present in the e-liquid. At 215°C, the estimated daily exposure to formaldehyde from e-cigarettes, exceeded United States Environmental Protection Agency (USEPA) and California Office of Environmental Health Hazard Assessment (OEHHA) acceptable limits, which emphasized the need to further examine the potential cancer and non-cancer health risks associated with e-cigarette use.

Open-access reader

About this research paper

What this paper is about

OBJECTIVES: To investigate how the two main electronic (e-) cigarette solvents-propylene glycol (PG) and glycerol (GL)-modulate the formation of toxic volatile carbonyl compounds under precisely controlled temperatures in the absence of nicotine and flavor additives. METHODS: PG, GL, PG:GL = 1:1 (wt/wt) mixture, and two commercial e-cigarette liquids were vaporized in a stainless steel, tubular reactor in flowing air ranging up to 318°C to simulate e-cigarette vaping. Aerosols were collected and analyzed to quantify the amount of volatile carbonyls produced with each of the five e-liquids. RESULTS: Significant amounts of formaldehyde and acetaldehyde were detected at reactor temperatures ≥215°C for both PG and GL. Acrolein was observed only in e-liquids containing GL when reactor temperatures exceeded 270°C. At 318°C, 2.03±0.80 μg of formaldehyde, 2.35±0.87 μg of acetaldehyde, and a trace amount of acetone were generated per milligram of PG; at the same temperature, 21.1±3.80 μg of formaldehyde, 2.40±0.99 μg of acetaldehyde, and 0.80±0.50 μg of acrolein were detected per milligram of GL. CONCLUSIONS: We developed a device-independent test method to investigate carbonyl emissions from different e-cigarette liquids under precisely controlled temperatures. PG and GL were identified to be the main sources of toxic carbonyl compounds from e-cigarette use. GL produced much more formaldehyde than PG. Besides formaldehyde and acetaldehyde, measurable amounts of acrolein were also detected at ≥270°C but only when GL was present in the e-liquid. At 215°C, the estimated daily exposure to formaldehyde from e-cigarettes, exceeded United States Environmental Protection Agency (USEPA) and California Office of Environmental Health Hazard Assessment (OEHHA) acceptable limits, which emphasized the need to further examine the potential cancer and non-cancer health risks associated with e-cigarette use.

Why it matters

OpenAlex reports 137 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To investigate how the two main electronic (e-) cigarette solvents-propylene glycol (PG) and glycerol (GL)-modulate the formation of toxic volatile carbonyl compounds under precisely controlled temperatures in the absence of nicotine and flavor additives. METHODS: PG, GL, PG:GL = 1:1 (wt/wt) mixture, and two commercial e-cigarette liquids were vaporized in a stainless steel, tubular reactor in flowing air ranging up to 318°C to simulate e-cigarette vaping. Aerosols were collected and analyzed to quantify the amount of volatile carbonyls produced with each of the five e-liquids. RESULTS: Significant amounts of formaldehyde and acetaldehyde were detected at reactor temperatures ≥215°C for both PG and GL. Acrolein was observed only in e-liquids containing GL when reactor temperatures exceeded 270°C. At 318°C, 2.03±0.80 μg of formaldehyde, 2.35±0.87 μg of acetaldehyde, and a trace amount of acetone were generated per milligram of PG; at the same temperature, 21.1±3.80 μg of formaldehyde, 2.40±0.99 μg of acetaldehyde, and 0.80±0.50 μg of acrolein were detected per milligram of GL. CONCLUSIONS: We developed a device-independent test method to investigate carbonyl emissions from different e-cigarette liquids under precisely controlled temperatures. PG and GL were identified to be the main sources of toxic carbonyl compounds from e-cigarette use. GL produced much more formaldehyde than PG. Besides formaldehyde and acetaldehyde, measurable amounts of acrolein were also detected at ≥270°C but only when GL was present in the e-liquid. At 215°C, the estimated daily exposure to formaldehyde from e-cigarettes, exceeded United States Environmental Protection Agency (USEPA) and California Office of Environmental Health Hazard Assessment (OEHHA) acceptable limits, which emphasized the need to further examine the potential cancer and non-cancer health risks associated with e-cigarette use.

Key concepts: Acrolein, Formaldehyde, Acetaldehyde, Acetone, Chemistry, Electronic cigarette, Nuclear chemistry, Glycerol

Related papers

Back to paper searchBrowse research topicsOriginal source
A Device-Independent Evaluation of Carbonyl Emissions from Heated Electronic Cigarette Solvents — Research Paper | ScholarLens