2013TU/e Research PortalOpen access

Field evaluation of the performance of a radiant heating/cooling ceiling panel system

Rongling Li, Ryozo Ooka, Bjarne W. Olesen

Open full text 0 citations

Abstract

As in many other countries in the world, Japan has witnessed an increased focus on low-energy buildings. For testing different engineering solutions for energy-efficient buildings, a low-energy building was built at the University of Tokyo as an experimental pilot project. In this building, a radiant heating/cooling ceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiant heating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus, this study aims to not only clarify the system performance but also to share our experience and our results for them to serve as a reference for other similar projects. Here, the system performance in relation to its heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient from water to room was 3.7 W/(m2 K) and 4.8 W/(m2 K) for heating and cooling cases, respectively. The upward heat flux from the panels was found to be as large as 30–40% of the water heating/cooling capacity; this would translate into heat loss in certain operating modes. Several proposals for reducing the upward heat flux were discussed. The measurements also showed that a category B thermal environment was obtained using the radiant ceiling heating/cooling system.

About this research paper

What this paper is about

As in many other countries in the world, Japan has witnessed an increased focus on low-energy buildings. For testing different engineering solutions for energy-efficient buildings, a low-energy building was built at the University of Tokyo as an experimental pilot project. In this building, a radiant heating/cooling ceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiant heating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus, this study aims to not only clarify the system performance but also to share our experience and our results for them to serve as a reference for other similar projects. Here, the system performance in relation to its heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient from water to room was 3.7 W/(m2 K) and 4.8 W/(m2 K) for heating and cooling cases, respectively. The upward heat flux from the panels was found to be as large as 30–40% of the water heating/cooling capacity; this would translate into heat loss in certain operating modes. Several proposals for reducing the upward heat flux were discussed. The measurements also showed that a category B thermal environment was obtained using the radiant ceiling heating/cooling system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As in many other countries in the world, Japan has witnessed an increased focus on low-energy buildings. For testing different engineering solutions for energy-efficient buildings, a low-energy building was built at the University of Tokyo as an experimental pilot project. In this building, a radiant heating/cooling ceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiant heating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus, this study aims to not only clarify the system performance but also to share our experience and our results for them to serve as a reference for other similar projects. Here, the system performance in relation to its heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient from water to room was 3.7 W/(m2 K) and 4.8 W/(m2 K) for heating and cooling cases, respectively. The upward heat flux from the panels was found to be as large as 30–40% of the water heating/cooling capacity; this would translate into heat loss in certain operating modes. Several proposals for reducing the upward heat flux were discussed. The measurements also showed that a category B thermal environment was obtained using the radiant ceiling heating/cooling system.

Key concepts: Ceiling (cloud), Radiant cooling, Environmental science, Field (mathematics), Radiant heat, Radiant heating, Meteorology, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Field evaluation of the performance of a radiant heating/cooling ceiling panel system — Research Paper | ScholarLens