2008Analytical chemistry, an Indian journalRequires access

Difference spectrophotometric andRP-HPLCmethods for simultaneous determination of aceclofenac and paracetamol in combined tablet dosage form

Poonam P. Patil, Smita S. Aher, Veena Sanjay Kasture

Open publisher page 0 citations

Abstract

A simple difference spectrophotometricmethod has been developed for the estimation of aceclofenac and paracetamol frompharmaceutical dosage form. The change in pH altered the absorption spectra of aceclofenac and paracetamol. Differential spectrumof paracetamol and aceclofenac in alkaline and acidic solution showedmaximumabsorbance at 267 nmand 246 nm and minimum at 232 nm and 276 nm respectively. Measurement of absorbance was carried out at zero-crossing wavelength 247 nmfor paracetamol and 256.7nm for aceclofenac. BeerÂ’s law was valid in the concentration range of 1-20i­g/ml for aceclofenac and 1-50 µg/ml for paracetamol. This method was validated for precision (n=6) and accuracy (100.15 i‚±0.761 %) and (99.73i‚±0.436 %) respectively (n=3) at each level. The reverse phase high performance liquid chromatographic (RP-HPLC), has been developed and validated for the simultaneous estimation of paracetamol (PARA) and aceclofenac (ACE) in tablet dosage form.WatersC18 Octadecyl Silane (ODS) column (250 i‚´ 4.6mmi. d., 5i­ particle size) in isocraticmodewas used. The mobile phase used was acetonitrile: 50 mM sodium dihydrogen phosphate (50:50) v/v, pH3.0 ± 0.1 with orthophosphoric acid. The flow rate was 1.5 mL per minute and eluent was monitored at 276 nm. The retention times of PARAand ACE were found to be 1.92 min and 9.28 min respectively. The linearity for paracetamol and aceclofenac were in the range of 5 - 50i­g /mL and 1.0 - 10i­g /mL respectively (n=6). Percentage recoveries obtained for paracetamol and aceclofenac were 100.7% and 100.4 % respectively. The relative standard deviationwas found to be 1.78%and 1.80%for paracetamol and aceclofenac in triplicate analysis. Thus the proposed methods are precise, accurate, selective and rapid for simultaneous estimation of paracetamol and aceclofenac in tablet formulation.

About this research paper

What this paper is about

A simple difference spectrophotometricmethod has been developed for the estimation of aceclofenac and paracetamol frompharmaceutical dosage form. The change in pH altered the absorption spectra of aceclofenac and paracetamol. Differential spectrumof paracetamol and aceclofenac in alkaline and acidic solution showedmaximumabsorbance at 267 nmand 246 nm and minimum at 232 nm and 276 nm respectively. Measurement of absorbance was carried out at zero-crossing wavelength 247 nmfor paracetamol and 256.7nm for aceclofenac. BeerÂ’s law was valid in the concentration range of 1-20i­g/ml for aceclofenac and 1-50 µg/ml for paracetamol. This method was validated for precision (n=6) and accuracy (100.15 i‚±0.761 %) and (99.73i‚±0.436 %) respectively (n=3) at each level. The reverse phase high performance liquid chromatographic (RP-HPLC), has been developed and validated for the simultaneous estimation of paracetamol (PARA) and aceclofenac (ACE) in tablet dosage form.WatersC18 Octadecyl Silane (ODS) column (250 i‚´ 4.6mmi. d., 5i­ particle size) in isocraticmodewas used. The mobile phase used was acetonitrile: 50 mM sodium dihydrogen phosphate (50:50) v/v, pH3.0 ± 0.1 with orthophosphoric acid. The flow rate was 1.5 mL per minute and eluent was monitored at 276 nm. The retention times of PARAand ACE were found to be 1.92 min and 9.28 min respectively. The linearity for paracetamol and aceclofenac were in the range of 5 - 50i­g /mL and 1.0 - 10i­g /mL respectively (n=6). Percentage recoveries obtained for paracetamol and aceclofenac were 100.7% and 100.4 % respectively. The relative standard deviationwas found to be 1.78%and 1.80%for paracetamol and aceclofenac in triplicate analysis. Thus the proposed methods are precise, accurate, selective and rapid for simultaneous estimation of paracetamol and aceclofenac in tablet formulation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple difference spectrophotometricmethod has been developed for the estimation of aceclofenac and paracetamol frompharmaceutical dosage form. The change in pH altered the absorption spectra of aceclofenac and paracetamol. Differential spectrumof paracetamol and aceclofenac in alkaline and acidic solution showedmaximumabsorbance at 267 nmand 246 nm and minimum at 232 nm and 276 nm respectively. Measurement of absorbance was carried out at zero-crossing wavelength 247 nmfor paracetamol and 256.7nm for aceclofenac. BeerÂ’s law was valid in the concentration range of 1-20i­g/ml for aceclofenac and 1-50 µg/ml for paracetamol. This method was validated for precision (n=6) and accuracy (100.15 i‚±0.761 %) and (99.73i‚±0.436 %) respectively (n=3) at each level. The reverse phase high performance liquid chromatographic (RP-HPLC), has been developed and validated for the simultaneous estimation of paracetamol (PARA) and aceclofenac (ACE) in tablet dosage form.WatersC18 Octadecyl Silane (ODS) column (250 i‚´ 4.6mmi. d., 5i­ particle size) in isocraticmodewas used. The mobile phase used was acetonitrile: 50 mM sodium dihydrogen phosphate (50:50) v/v, pH3.0 ± 0.1 with orthophosphoric acid. The flow rate was 1.5 mL per minute and eluent was monitored at 276 nm. The retention times of PARAand ACE were found to be 1.92 min and 9.28 min respectively. The linearity for paracetamol and aceclofenac were in the range of 5 - 50i­g /mL and 1.0 - 10i­g /mL respectively (n=6). Percentage recoveries obtained for paracetamol and aceclofenac were 100.7% and 100.4 % respectively. The relative standard deviationwas found to be 1.78%and 1.80%for paracetamol and aceclofenac in triplicate analysis. Thus the proposed methods are precise, accurate, selective and rapid for simultaneous estimation of paracetamol and aceclofenac in tablet formulation.

Key concepts: Aceclofenac, Chromatography, Chemistry, Dosage form, Absorbance, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Difference spectrophotometric andRP-HPLCmethods for simultaneous determination of aceclofenac and paracetamol in combined tablet dosage form — Research Paper | ScholarLens