2011•Orthopaedic ProceedingsRequires access

COMPARISON OF TENSION BAND AND INTERFRAGMENTARY SCREW FIXATION WITH A NEW IMPLANT IN TRANSVERSE PATELLA FRACTURES – A BIOMECHANICAL INVESTIGATION

Sascha Gick, Jens Dargel, Boris Wissussek, Juergen Koebke, Dietmar Pennig

Open publisher page 0 citations

Abstract

The aim of this study was to compare the primary fixation stability and initial fixation stiffness of two commonly used fixation techniques, the tension band wiring technique and interfragmentary screw fixation, with an innovative mini-screw fragment fixation system in a model of transverse fracture of the patella. It was hypothesized that the biomechanical performance of the fragment fixation system would not significantly differ from the loading characteristics of the two established methods currently investigated. Materials and Methods: A standardized transverse patella fracture was induced in ninety-six calf patella and three different fixation methods, including the mod-ified tension band wiring technique, interfragmentary screw fixation, and the mini-screw fragment fixation system, were used for fragment fixation. Specimens were mounted to a loading rig which was integrated within a material testing machine. In each fixation group, eight specimens were loaded to failure at varying simulated knee angles of either 0° or 45°. Another eight specimens were submitted to polycyclic loading consisting of 30 cycles between 20 N and 300 N at a simulated knee angle of either 0° or 45°. The residual displacement between the first and the last cycle was recorded. Differences in the biomechanical performance between the three fixation groups were evaluated. Results: With monocyclic loading, no significant differences between the three groups were observed in the parameters maximum load to failure and linear fixation stiffness. Specimens loaded at 45° showed significantly lower maximum failure loads and linear stiffness when compared with 0° knee angle. With polycyclic loading, no significant differences in the residual displacement were observed between the groups at 0° loading angle, while at 45°, residual displacement was significantly higher with tension band fixation when compared with interfragmentary screw fixation or the fragment fixation system. Conclusion: This study confirmed that the biomechanical performance of the fragment fixation system was comparable to interfragmentary screw fixation and superior to the tension band wiring technique. As the fragment fixation system combines the advantages of providing interfragmentary compression with percutaneous pin insertion after closed reduction, we believe the fragment fixation system to be an adequate alternative in the osteosynthesis of transverse patella fractures.

About this research paper

What this paper is about

The aim of this study was to compare the primary fixation stability and initial fixation stiffness of two commonly used fixation techniques, the tension band wiring technique and interfragmentary screw fixation, with an innovative mini-screw fragment fixation system in a model of transverse fracture of the patella. It was hypothesized that the biomechanical performance of the fragment fixation system would not significantly differ from the loading characteristics of the two established methods currently investigated. Materials and Methods: A standardized transverse patella fracture was induced in ninety-six calf patella and three different fixation methods, including the mod-ified tension band wiring technique, interfragmentary screw fixation, and the mini-screw fragment fixation system, were used for fragment fixation. Specimens were mounted to a loading rig which was integrated within a material testing machine. In each fixation group, eight specimens were loaded to failure at varying simulated knee angles of either 0° or 45°. Another eight specimens were submitted to polycyclic loading consisting of 30 cycles between 20 N and 300 N at a simulated knee angle of either 0° or 45°. The residual displacement between the first and the last cycle was recorded. Differences in the biomechanical performance between the three fixation groups were evaluated. Results: With monocyclic loading, no significant differences between the three groups were observed in the parameters maximum load to failure and linear fixation stiffness. Specimens loaded at 45° showed significantly lower maximum failure loads and linear stiffness when compared with 0° knee angle. With polycyclic loading, no significant differences in the residual displacement were observed between the groups at 0° loading angle, while at 45°, residual displacement was significantly higher with tension band fixation when compared with interfragmentary screw fixation or the fragment fixation system. Conclusion: This study confirmed that the biomechanical performance of the fragment fixation system was comparable to interfragmentary screw fixation and superior to the tension band wiring technique. As the fragment fixation system combines the advantages of providing interfragmentary compression with percutaneous pin insertion after closed reduction, we believe the fragment fixation system to be an adequate alternative in the osteosynthesis of transverse patella fractures.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to compare the primary fixation stability and initial fixation stiffness of two commonly used fixation techniques, the tension band wiring technique and interfragmentary screw fixation, with an innovative mini-screw fragment fixation system in a model of transverse fracture of the patella. It was hypothesized that the biomechanical performance of the fragment fixation system would not significantly differ from the loading characteristics of the two established methods currently investigated. Materials and Methods: A standardized transverse patella fracture was induced in ninety-six calf patella and three different fixation methods, including the mod-ified tension band wiring technique, interfragmentary screw fixation, and the mini-screw fragment fixation system, were used for fragment fixation. Specimens were mounted to a loading rig which was integrated within a material testing machine. In each fixation group, eight specimens were loaded to failure at varying simulated knee angles of either 0° or 45°. Another eight specimens were submitted to polycyclic loading consisting of 30 cycles between 20 N and 300 N at a simulated knee angle of either 0° or 45°. The residual displacement between the first and the last cycle was recorded. Differences in the biomechanical performance between the three fixation groups were evaluated. Results: With monocyclic loading, no significant differences between the three groups were observed in the parameters maximum load to failure and linear fixation stiffness. Specimens loaded at 45° showed significantly lower maximum failure loads and linear stiffness when compared with 0° knee angle. With polycyclic loading, no significant differences in the residual displacement were observed between the groups at 0° loading angle, while at 45°, residual displacement was significantly higher with tension band fixation when compared with interfragmentary screw fixation or the fragment fixation system. Conclusion: This study confirmed that the biomechanical performance of the fragment fixation system was comparable to interfragmentary screw fixation and superior to the tension band wiring technique. As the fragment fixation system combines the advantages of providing interfragmentary compression with percutaneous pin insertion after closed reduction, we believe the fragment fixation system to be an adequate alternative in the osteosynthesis of transverse patella fractures.

Key concepts: Fixation (population genetics), Patella fracture, Materials science, Stiffness, Orthodontics, Biomechanics, Transverse plane, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
COMPARISON OF TENSION BAND AND INTERFRAGMENTARY SCREW FIXATION WITH A NEW IMPLANT IN TRANSVERSE PATELLA FRACTURES – A BIOMECHANICAL INVESTIGATION — Research Paper | ScholarLens