2016BioMedical Engineering OnLineOpen access

Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)

Jie Li, Xiaopeng Tian, Zhenze Wang, Jiang Xiong, Yubo Fan, Xiaoyan Deng, Anqiang Sun, Xiao Liu

Open full text 4 citations

Abstract

BACKGROUND: Abdominal aortic aneurysm (AAA) is a kind of dangerous aortic vascular disease, which is characterized by abdominal aorta partial enlargement. At present, endovascular aneurysm repair (EVAR) is one of the main treatments of abdominal aortic aneurysm. However for some patients after EVAR the aneurysm re-expanded and even ruptured, leading to poor postoperative effect. The stent-graft endoleak after EVAR was realized to influence the AAA in-sac pressure and contribute to the aneurysm re-enlargement. METHODS: In order to analyze the influence of endoleaks positions on the pressure shielding ability of stent-graft after EVAR, type I and type III endoleak models were reconstructed based on computed tomography (CT) scan images, and the hemodynamic environment in AAA was numerically simulated. RESULTS: When the endoleak was at the proximal position the pressure shielding ability will be obviously weakened. While, the pressure shielding ability was higher in the systole phase than that in diastole phase when the endoleak located at the middle or distal positions. Unfortunately, when the endoleak located at the proximal position, the pressure shielding ability would be relatively weak in the whole cardiac cycle. CONCLUSIONS: The results revealed that the influence of endoleaks on pressure shielding ability of stent-graft was both location and time specific.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Abdominal aortic aneurysm (AAA) is a kind of dangerous aortic vascular disease, which is characterized by abdominal aorta partial enlargement. At present, endovascular aneurysm repair (EVAR) is one of the main treatments of abdominal aortic aneurysm. However for some patients after EVAR the aneurysm re-expanded and even ruptured, leading to poor postoperative effect. The stent-graft endoleak after EVAR was realized to influence the AAA in-sac pressure and contribute to the aneurysm re-enlargement. METHODS: In order to analyze the influence of endoleaks positions on the pressure shielding ability of stent-graft after EVAR, type I and type III endoleak models were reconstructed based on computed tomography (CT) scan images, and the hemodynamic environment in AAA was numerically simulated. RESULTS: When the endoleak was at the proximal position the pressure shielding ability will be obviously weakened. While, the pressure shielding ability was higher in the systole phase than that in diastole phase when the endoleak located at the middle or distal positions. Unfortunately, when the endoleak located at the proximal position, the pressure shielding ability would be relatively weak in the whole cardiac cycle. CONCLUSIONS: The results revealed that the influence of endoleaks on pressure shielding ability of stent-graft was both location and time specific.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Abdominal aortic aneurysm (AAA) is a kind of dangerous aortic vascular disease, which is characterized by abdominal aorta partial enlargement. At present, endovascular aneurysm repair (EVAR) is one of the main treatments of abdominal aortic aneurysm. However for some patients after EVAR the aneurysm re-expanded and even ruptured, leading to poor postoperative effect. The stent-graft endoleak after EVAR was realized to influence the AAA in-sac pressure and contribute to the aneurysm re-enlargement. METHODS: In order to analyze the influence of endoleaks positions on the pressure shielding ability of stent-graft after EVAR, type I and type III endoleak models were reconstructed based on computed tomography (CT) scan images, and the hemodynamic environment in AAA was numerically simulated. RESULTS: When the endoleak was at the proximal position the pressure shielding ability will be obviously weakened. While, the pressure shielding ability was higher in the systole phase than that in diastole phase when the endoleak located at the middle or distal positions. Unfortunately, when the endoleak located at the proximal position, the pressure shielding ability would be relatively weak in the whole cardiac cycle. CONCLUSIONS: The results revealed that the influence of endoleaks on pressure shielding ability of stent-graft was both location and time specific.

Key concepts: Abdominal aortic aneurysm, Medicine, Endovascular aneurysm repair, Aneurysm, Stent, Radiology, Aortic aneurysm, Abdominal aorta

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) — Research Paper | ScholarLens