2016Rare MetalsRequires access

Corrosion behavior of three Ag–50Cu alloys prepared by different processes in NaCl solutions

Zhongqiu Jia, Qiu-Ying Liang, Qiu-yue TIAN, Zhongqiu Cao, Yan Wang

Open publisher page 3 citations

Abstract

Abstract Corrosion behavior of two nanocrystalline bulk Ag–50Cu alloys and one coarse‐grained counterpart prepared by liquid‐phase reduction (LPR), mechanical alloying (MA) and powder metallurgy (PM) methods, respectively, were investigated in NaCl solutions. They were finished by means of PARM273A and M5210 electrochemical apparatus through potentiodynamic polarization method and electrochemical impedance spectroscopy (EIS) technique. The results show that corrosion rates of three Ag–50Cu alloys increase with the increment of NaCl solution concentrations. Corrosion rates of LPRAg–50Cu alloy are a little higher than those of PMAg–50Cu alloy, but evidently lower than those of MAAg–50Cu alloy. The difference in corrosion rates is attributed to the large reduction in the grain size and homogeneous microstructure of nanocrystalline alloys. Passive current densities decrease and afterward increase for PMAg–50Cu alloy, decrease for MAAg–50Cu alloy, and increase for LPRAg–50Cu alloy with the increment of NaCl solution concentrations. After the grain sizes are refined, passive current densities become lower.

About this research paper

What this paper is about

Abstract Corrosion behavior of two nanocrystalline bulk Ag–50Cu alloys and one coarse‐grained counterpart prepared by liquid‐phase reduction (LPR), mechanical alloying (MA) and powder metallurgy (PM) methods, respectively, were investigated in NaCl solutions. They were finished by means of PARM273A and M5210 electrochemical apparatus through potentiodynamic polarization method and electrochemical impedance spectroscopy (EIS) technique. The results show that corrosion rates of three Ag–50Cu alloys increase with the increment of NaCl solution concentrations. Corrosion rates of LPRAg–50Cu alloy are a little higher than those of PMAg–50Cu alloy, but evidently lower than those of MAAg–50Cu alloy. The difference in corrosion rates is attributed to the large reduction in the grain size and homogeneous microstructure of nanocrystalline alloys. Passive current densities decrease and afterward increase for PMAg–50Cu alloy, decrease for MAAg–50Cu alloy, and increase for LPRAg–50Cu alloy with the increment of NaCl solution concentrations. After the grain sizes are refined, passive current densities become lower.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Corrosion behavior of two nanocrystalline bulk Ag–50Cu alloys and one coarse‐grained counterpart prepared by liquid‐phase reduction (LPR), mechanical alloying (MA) and powder metallurgy (PM) methods, respectively, were investigated in NaCl solutions. They were finished by means of PARM273A and M5210 electrochemical apparatus through potentiodynamic polarization method and electrochemical impedance spectroscopy (EIS) technique. The results show that corrosion rates of three Ag–50Cu alloys increase with the increment of NaCl solution concentrations. Corrosion rates of LPRAg–50Cu alloy are a little higher than those of PMAg–50Cu alloy, but evidently lower than those of MAAg–50Cu alloy. The difference in corrosion rates is attributed to the large reduction in the grain size and homogeneous microstructure of nanocrystalline alloys. Passive current densities decrease and afterward increase for PMAg–50Cu alloy, decrease for MAAg–50Cu alloy, and increase for LPRAg–50Cu alloy with the increment of NaCl solution concentrations. After the grain sizes are refined, passive current densities become lower.

Key concepts: Materials science, Nanocrystalline material, Alloy, Corrosion, Metallurgy, Dielectric spectroscopy, Microstructure, Grain size

Related papers

Back to paper searchBrowse research topicsOriginal source
Corrosion behavior of three Ag–50Cu alloys prepared by different processes in NaCl solutions — Research Paper | ScholarLens