2016Journal of Separation ScienceRequires access

Simultaneous determination of trimethylamine and trimethylamine N‐oxide in mouse plasma samples by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry

Si Mi, Yuanyuan Zhao, René L. Jacobs, Jonathan M. Curtis

Open publisher page 29 citations

Abstract

A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N-oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N-oxide using positive-ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N-oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N-oxide. Method accuracies of 91.4-105.3% with precisions of 0.4-5.5% were obtained for standard mixtures over the range of 2.5-500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N-oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N-oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.

About this research paper

What this paper is about

A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N-oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N-oxide using positive-ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N-oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N-oxide. Method accuracies of 91.4-105.3% with precisions of 0.4-5.5% were obtained for standard mixtures over the range of 2.5-500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N-oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N-oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N-oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N-oxide using positive-ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N-oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N-oxide. Method accuracies of 91.4-105.3% with precisions of 0.4-5.5% were obtained for standard mixtures over the range of 2.5-500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N-oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N-oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.

Key concepts: Trimethylamine, Trimethylamine N-oxide, Chromatography, Chemistry, Tandem mass spectrometry, Mass spectrometry, Liquid chromatography–mass spectrometry, Tandem

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of trimethylamine and trimethylamine N‐oxide in mouse plasma samples by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry — Research Paper | ScholarLens