Simultaneous determination of trimethylamine and trimethylamine N‐oxide in mouse plasma samples by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry
Si Mi, Yuanyuan Zhao, René L. Jacobs, Jonathan M. Curtis
Abstract
Si Mi, Yuanyuan Zhao, René L. Jacobs, Jonathan M. Curtis
Abstract
A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N-oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N-oxide using positive-ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N-oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N-oxide. Method accuracies of 91.4-105.3% with precisions of 0.4-5.5% were obtained for standard mixtures over the range of 2.5-500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N-oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N-oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.
OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N-oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N-oxide using positive-ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N-oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N-oxide. Method accuracies of 91.4-105.3% with precisions of 0.4-5.5% were obtained for standard mixtures over the range of 2.5-500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N-oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N-oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.
Key concepts: Trimethylamine, Trimethylamine N-oxide, Chromatography, Chemistry, Tandem mass spectrometry, Mass spectrometry, Liquid chromatography–mass spectrometry, Tandem