2015•JACOWOpen access

Thermal and Structural Analysis of the 72.75 MHz LINCE RFQ

Angie Orduz, Aurelio Berjillos, C. Bonţoiu, J. A. Dueñas, Alberto Garbayo, Martel, Ismael

Open full text 1 citations

Abstract

The 72.75 MHz LINCE RFQ is designed to function at room temperature. Effective operation of the RFQ cavity requires efficient water cooling in order to dissipate significant resistive power non-uniformly distributed on the copper walls and vanes. This amounts to about 10 kWfor one 0.5m long RFQ section. Cylindrical cooling channels have been designed and optimized by varying their diameter and position in order to minimize the frequency shift generated by thermal displacements. The article reports results of power loss simulations coupled with electromagnetic modelling studies and their consequences on the RFQ performance in terms of resonant frequency and thermal deformations.

About this research paper

What this paper is about

The 72.75 MHz LINCE RFQ is designed to function at room temperature. Effective operation of the RFQ cavity requires efficient water cooling in order to dissipate significant resistive power non-uniformly distributed on the copper walls and vanes. This amounts to about 10 kWfor one 0.5m long RFQ section. Cylindrical cooling channels have been designed and optimized by varying their diameter and position in order to minimize the frequency shift generated by thermal displacements. The article reports results of power loss simulations coupled with electromagnetic modelling studies and their consequences on the RFQ performance in terms of resonant frequency and thermal deformations.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The 72.75 MHz LINCE RFQ is designed to function at room temperature. Effective operation of the RFQ cavity requires efficient water cooling in order to dissipate significant resistive power non-uniformly distributed on the copper walls and vanes. This amounts to about 10 kWfor one 0.5m long RFQ section. Cylindrical cooling channels have been designed and optimized by varying their diameter and position in order to minimize the frequency shift generated by thermal displacements. The article reports results of power loss simulations coupled with electromagnetic modelling studies and their consequences on the RFQ performance in terms of resonant frequency and thermal deformations.

Key concepts: Environmental science, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source