2012•Unpublished venueRequires access

Cross-Weld Creep Comparison of Power Plant Steels CrMoV, P91 and P92

David W. J. Tanner, Wei Sun, Thomas H. Hyde

Open publisher page 1 citations

Abstract

Results obtained from high temperature creep tests of ferritic steel CrMoV, P91 and P92 cross-weld specimens are compared. Data is presented normalized with the results of the corresponding parent metals in order to compare the materials tested at different temperatures and stresses, and to identify characteristic cross-weld material trends. All cross-weld failures occurred in the heat-affected zone (HAZ) adjacent to the parent metal, known as type IV, at earlier test durations than for the parent material specimens. The relative performance of the cross-welds was found to decrease with decreasing stress. The CrMoV cross-weld specimens showed by far the lowest weld strength reduction factors and greatest notch strengthening, determined by testing uniaxially loaded bars with semi-circular circumferential notches located in the heat-affected zone. The P91 and P92 cross-weld specimens were found to have similar (high) weld strength reduction factors and showed little or no notch strengthening. It was observed that the failure time of a P92 cross-weld specimen relative to the P92 parent material could be estimated using data from P91 cross-weld and relative parent material tests.

About this research paper

What this paper is about

Results obtained from high temperature creep tests of ferritic steel CrMoV, P91 and P92 cross-weld specimens are compared. Data is presented normalized with the results of the corresponding parent metals in order to compare the materials tested at different temperatures and stresses, and to identify characteristic cross-weld material trends. All cross-weld failures occurred in the heat-affected zone (HAZ) adjacent to the parent metal, known as type IV, at earlier test durations than for the parent material specimens. The relative performance of the cross-welds was found to decrease with decreasing stress. The CrMoV cross-weld specimens showed by far the lowest weld strength reduction factors and greatest notch strengthening, determined by testing uniaxially loaded bars with semi-circular circumferential notches located in the heat-affected zone. The P91 and P92 cross-weld specimens were found to have similar (high) weld strength reduction factors and showed little or no notch strengthening. It was observed that the failure time of a P92 cross-weld specimen relative to the P92 parent material could be estimated using data from P91 cross-weld and relative parent material tests.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Results obtained from high temperature creep tests of ferritic steel CrMoV, P91 and P92 cross-weld specimens are compared. Data is presented normalized with the results of the corresponding parent metals in order to compare the materials tested at different temperatures and stresses, and to identify characteristic cross-weld material trends. All cross-weld failures occurred in the heat-affected zone (HAZ) adjacent to the parent metal, known as type IV, at earlier test durations than for the parent material specimens. The relative performance of the cross-welds was found to decrease with decreasing stress. The CrMoV cross-weld specimens showed by far the lowest weld strength reduction factors and greatest notch strengthening, determined by testing uniaxially loaded bars with semi-circular circumferential notches located in the heat-affected zone. The P91 and P92 cross-weld specimens were found to have similar (high) weld strength reduction factors and showed little or no notch strengthening. It was observed that the failure time of a P92 cross-weld specimen relative to the P92 parent material could be estimated using data from P91 cross-weld and relative parent material tests.

Key concepts: Welding, Materials science, Creep, Metallurgy, Heat-affected zone, Composite material, Stress (linguistics), Philosophy

Related papers

Back to paper searchBrowse research topicsOriginal source
Cross-Weld Creep Comparison of Power Plant Steels CrMoV, P91 and P92 — Research Paper | ScholarLens