2017•viXraRequires access

Simultaneous Estimation of Emtricitabine and Tenofovir Disoproxil Fumarate in Tablet Dosage Form by Reverse Phase High-performance Liquid Chromatography

Bala Rami Reddy.Yenumula, Mutta Reddy.Singampalli, Bala Sekhara Reddy Challa

Open publisher page 1 citations

Abstract

A simple, rapid reversed-phase high performance liquid chromatographic method had been developed and validated for estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. The estimation was carried out on PhenomenexLuna C18 (25 cm x 4.60 mm, particle size 5 µm) column with a mixture of 10mM phosphate buffer (pH 6.8): Acetonitrile; 40: 60 (v/v) as mobile phase. UV detection was performed at 260 nm. The method was validated for linearity, accuracy, precision, specificity and sensitivity as per ICH norms. The developed and validated method was successfully used for the quantitative analysis of commercially available dosage form. The retention time was 2.81 and 7.42 min for emtricitabine and tenofovir disoproxil fumarate respectively and total run time was 10 min. at a flow rate of 1.0 mL/ min. The calibration curve was linear over the concentration range of 40.00 - 240.00 µg/ mL for emtricitabine and 60.00 - 360.00 µg/ mL for tenofovir disoproxil fumarate. The LOD and LOQ values were found to be 1.54 and 4.54 µg/ mL for emtricitabine and 4.60 and 13.65 µg/ mL for tenofovir disoproxil fumarate respectively. The high percentage of recovery and low percentage coefficient of variance confirm the suitability of the method for the simultaneous estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. You can submit your Manuscripts at:  https://symbiosisonlinepublishing.com/submitManuscript.php

About this research paper

What this paper is about

A simple, rapid reversed-phase high performance liquid chromatographic method had been developed and validated for estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. The estimation was carried out on PhenomenexLuna C18 (25 cm x 4.60 mm, particle size 5 µm) column with a mixture of 10mM phosphate buffer (pH 6.8): Acetonitrile; 40: 60 (v/v) as mobile phase. UV detection was performed at 260 nm. The method was validated for linearity, accuracy, precision, specificity and sensitivity as per ICH norms. The developed and validated method was successfully used for the quantitative analysis of commercially available dosage form. The retention time was 2.81 and 7.42 min for emtricitabine and tenofovir disoproxil fumarate respectively and total run time was 10 min. at a flow rate of 1.0 mL/ min. The calibration curve was linear over the concentration range of 40.00 - 240.00 µg/ mL for emtricitabine and 60.00 - 360.00 µg/ mL for tenofovir disoproxil fumarate. The LOD and LOQ values were found to be 1.54 and 4.54 µg/ mL for emtricitabine and 4.60 and 13.65 µg/ mL for tenofovir disoproxil fumarate respectively. The high percentage of recovery and low percentage coefficient of variance confirm the suitability of the method for the simultaneous estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. You can submit your Manuscripts at:  https://symbiosisonlinepublishing.com/submitManuscript.php

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, rapid reversed-phase high performance liquid chromatographic method had been developed and validated for estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. The estimation was carried out on PhenomenexLuna C18 (25 cm x 4.60 mm, particle size 5 µm) column with a mixture of 10mM phosphate buffer (pH 6.8): Acetonitrile; 40: 60 (v/v) as mobile phase. UV detection was performed at 260 nm. The method was validated for linearity, accuracy, precision, specificity and sensitivity as per ICH norms. The developed and validated method was successfully used for the quantitative analysis of commercially available dosage form. The retention time was 2.81 and 7.42 min for emtricitabine and tenofovir disoproxil fumarate respectively and total run time was 10 min. at a flow rate of 1.0 mL/ min. The calibration curve was linear over the concentration range of 40.00 - 240.00 µg/ mL for emtricitabine and 60.00 - 360.00 µg/ mL for tenofovir disoproxil fumarate. The LOD and LOQ values were found to be 1.54 and 4.54 µg/ mL for emtricitabine and 4.60 and 13.65 µg/ mL for tenofovir disoproxil fumarate respectively. The high percentage of recovery and low percentage coefficient of variance confirm the suitability of the method for the simultaneous estimation of emtricitabine and tenofovir disoproxil fumarate in tablet dosage form. You can submit your Manuscripts at:  https://symbiosisonlinepublishing.com/submitManuscript.php

Key concepts: Emtricitabine, Tenofovir, Chromatography, Dosage form, Chemistry, Retention time, Phosphate buffered saline, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Estimation of Emtricitabine and Tenofovir Disoproxil Fumarate in Tablet Dosage Form by Reverse Phase High-performance Liquid Chromatography — Research Paper | ScholarLens