2016Ear and HearingRequires access

Fast Click Rate Electrocochleography and Auditory Brainstem Response in Normal-Hearing Adults Using Continuous Loop Averaging Deconvolution

Wafaa A. Kaf, Kelly M. Lewis, Yavuz Erdem, Samantha Dixon, Mark Van Ess, Abdullah M. Jamos, Rafael E. Delgado

Open publisher page 11 citations

Abstract

OBJECTIVES: Using the continuous loop averaging deconvolution (CLAD) technique for conventional electrocochleography (ECochG) and auditory brainstem response (ABR) recordings, the effects of testing at high stimulus rates may have the potential to diagnose disorders of the inner ear and auditory nerve. First, a body of normative data using the CLAD technique must be established. DESIGN: Extratympanic click ECochG and ABR to seven stimulus rates using CLAD were measured simultaneously from a tympanic membrane electrode and surface electrodes on the forehead and mastoid of 42 healthy individuals. RESULTS: Results showed that the compound action potential (AP) of the ECochG and waves I, III, and V of the ABR decreased in amplitude and increased in latency as stimulus rate was increased from standard 7.1 clicks/s up to 507.81 clicks/s, with sharp reduction in AP amplitude at 97.66 clicks/s and reaching asymptote at 292.97 clicks/s. The summating potential (SP) of the ECochG, however, stayed relatively stable, resulting in increased SP/AP ratios with increasing rate. The SP/AP amplitude ratio showed more stability than AP amplitude findings, thus it is recommended for use in evaluation of cochlear and neural response. CONCLUSIONS: Results of both amplitude and latency data from this normative neural adaptation function of the auditory pathway serves as guide for improving diagnostic utility of both ECochG and ABR using CLAD as a reliable technique in distinguishing inner ear and auditory nerve disorders.

About this research paper

What this paper is about

OBJECTIVES: Using the continuous loop averaging deconvolution (CLAD) technique for conventional electrocochleography (ECochG) and auditory brainstem response (ABR) recordings, the effects of testing at high stimulus rates may have the potential to diagnose disorders of the inner ear and auditory nerve. First, a body of normative data using the CLAD technique must be established. DESIGN: Extratympanic click ECochG and ABR to seven stimulus rates using CLAD were measured simultaneously from a tympanic membrane electrode and surface electrodes on the forehead and mastoid of 42 healthy individuals. RESULTS: Results showed that the compound action potential (AP) of the ECochG and waves I, III, and V of the ABR decreased in amplitude and increased in latency as stimulus rate was increased from standard 7.1 clicks/s up to 507.81 clicks/s, with sharp reduction in AP amplitude at 97.66 clicks/s and reaching asymptote at 292.97 clicks/s. The summating potential (SP) of the ECochG, however, stayed relatively stable, resulting in increased SP/AP ratios with increasing rate. The SP/AP amplitude ratio showed more stability than AP amplitude findings, thus it is recommended for use in evaluation of cochlear and neural response. CONCLUSIONS: Results of both amplitude and latency data from this normative neural adaptation function of the auditory pathway serves as guide for improving diagnostic utility of both ECochG and ABR using CLAD as a reliable technique in distinguishing inner ear and auditory nerve disorders.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: Using the continuous loop averaging deconvolution (CLAD) technique for conventional electrocochleography (ECochG) and auditory brainstem response (ABR) recordings, the effects of testing at high stimulus rates may have the potential to diagnose disorders of the inner ear and auditory nerve. First, a body of normative data using the CLAD technique must be established. DESIGN: Extratympanic click ECochG and ABR to seven stimulus rates using CLAD were measured simultaneously from a tympanic membrane electrode and surface electrodes on the forehead and mastoid of 42 healthy individuals. RESULTS: Results showed that the compound action potential (AP) of the ECochG and waves I, III, and V of the ABR decreased in amplitude and increased in latency as stimulus rate was increased from standard 7.1 clicks/s up to 507.81 clicks/s, with sharp reduction in AP amplitude at 97.66 clicks/s and reaching asymptote at 292.97 clicks/s. The summating potential (SP) of the ECochG, however, stayed relatively stable, resulting in increased SP/AP ratios with increasing rate. The SP/AP amplitude ratio showed more stability than AP amplitude findings, thus it is recommended for use in evaluation of cochlear and neural response. CONCLUSIONS: Results of both amplitude and latency data from this normative neural adaptation function of the auditory pathway serves as guide for improving diagnostic utility of both ECochG and ABR using CLAD as a reliable technique in distinguishing inner ear and auditory nerve disorders.

Key concepts: Electrocochleography, Audiology, Auditory brainstem response, Stimulus (psychology), Cochlear nerve, Compound muscle action potential, Brainstem, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Fast Click Rate Electrocochleography and Auditory Brainstem Response in Normal-Hearing Adults Using Continuous Loop Averaging Deconvolution — Research Paper | ScholarLens