RETRACTED ARTICLE: Identification of plastic hinge length for pre-tensioning confined HSC columns
Chau-Khun Ma, Abdullah Zawawi Awang, Wahid Omar
Abstract
Open-access reader
Chau-Khun Ma, Abdullah Zawawi Awang, Wahid Omar
Abstract
Open-access reader
The effects of pre-tensioned steel straps confinement in improving the plastic hinge length of High-Strength Concrete (HSC) columns was investigated in this study. In the design of confining works for a concrete members, the most difficult part is to determine the column’s region that needed to be confined. To ensure the confinement length that covered the column’s critical length is sufficient, the plastic hinge length is required to be identified beforehand, as confinement is only needed to cover the plastic hinge zone. This also can minimize the confining works as the region outside plastic hinge zone is not required. Six HSC columns were tested to monitor the variation in plastic hinge length due to pre-tensioned pressure. The plastic hinge length is determined based on the observation of strain developments of longitudinal steel bars. Detailed analysis proved that the steel straps confinement enhances the plastic hinge length when the confinement ratio is low. However, it was found that the positive effect reduces with the increase of the confinement ratio. Extensive comparison with the past studies revealed that the existing models were insufficient to predict the plastic hinge behaviour of HSC columns with pre-tensioning confinement. A new equation was proposed and it is sufficient be used as a guideline for the design of confining works using pre-tensioned steel straps confinement method.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The effects of pre-tensioned steel straps confinement in improving the plastic hinge length of High-Strength Concrete (HSC) columns was investigated in this study. In the design of confining works for a concrete members, the most difficult part is to determine the column’s region that needed to be confined. To ensure the confinement length that covered the column’s critical length is sufficient, the plastic hinge length is required to be identified beforehand, as confinement is only needed to cover the plastic hinge zone. This also can minimize the confining works as the region outside plastic hinge zone is not required. Six HSC columns were tested to monitor the variation in plastic hinge length due to pre-tensioned pressure. The plastic hinge length is determined based on the observation of strain developments of longitudinal steel bars. Detailed analysis proved that the steel straps confinement enhances the plastic hinge length when the confinement ratio is low. However, it was found that the positive effect reduces with the increase of the confinement ratio. Extensive comparison with the past studies revealed that the existing models were insufficient to predict the plastic hinge behaviour of HSC columns with pre-tensioning confinement. A new equation was proposed and it is sufficient be used as a guideline for the design of confining works using pre-tensioned steel straps confinement method.
Key concepts: Hinge, Plastic hinge, Structural engineering, Column (typography), Materials science, Engineering, Connection (principal bundle)