2016Qatar Foundation Annual Research Conference Proceedings Volume 2016 Issue 1Requires access

The Effect of Chilled Water Supply Temperature on the Energy Efficiency of the Chiller System

Abdulwahab Alyousef, Abdulwahab Bukshaisha

Open publisher page 0 citations

Abstract

A steady-state model for a centralized cooling system is developed and utilized to evaluate its energy efficiency. The numerical model resolves the energy equations for a cooling tower and a centralized water-cooled chiller simultaneously. It requires inputs that are readily available. The user-inputs are the ambient conditions, the cooling tower air flow rate, the condenser water flow rate, the evaporator water flow rate, the superheat and sub-cooling associated with the refrigeration cycle, and the full load design conditions. The model utilizes an empirical relationship for the compressor power as a function of load and temperature, and gives the user an option to select between a constant speed chiller and a variable speed chiller. The outputs include the chiller coefficient of performance, compressor input power and compressor isentropic efficiency. This talk will discuss the results of the assessment conducted of the effect of chilled water supply temperature on the performance and energy efficiency of the chiller system. The findings and recommendations on how to optimize chiller systems for best energy performance will also be presented.

About this research paper

What this paper is about

A steady-state model for a centralized cooling system is developed and utilized to evaluate its energy efficiency. The numerical model resolves the energy equations for a cooling tower and a centralized water-cooled chiller simultaneously. It requires inputs that are readily available. The user-inputs are the ambient conditions, the cooling tower air flow rate, the condenser water flow rate, the evaporator water flow rate, the superheat and sub-cooling associated with the refrigeration cycle, and the full load design conditions. The model utilizes an empirical relationship for the compressor power as a function of load and temperature, and gives the user an option to select between a constant speed chiller and a variable speed chiller. The outputs include the chiller coefficient of performance, compressor input power and compressor isentropic efficiency. This talk will discuss the results of the assessment conducted of the effect of chilled water supply temperature on the performance and energy efficiency of the chiller system. The findings and recommendations on how to optimize chiller systems for best energy performance will also be presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A steady-state model for a centralized cooling system is developed and utilized to evaluate its energy efficiency. The numerical model resolves the energy equations for a cooling tower and a centralized water-cooled chiller simultaneously. It requires inputs that are readily available. The user-inputs are the ambient conditions, the cooling tower air flow rate, the condenser water flow rate, the evaporator water flow rate, the superheat and sub-cooling associated with the refrigeration cycle, and the full load design conditions. The model utilizes an empirical relationship for the compressor power as a function of load and temperature, and gives the user an option to select between a constant speed chiller and a variable speed chiller. The outputs include the chiller coefficient of performance, compressor input power and compressor isentropic efficiency. This talk will discuss the results of the assessment conducted of the effect of chilled water supply temperature on the performance and energy efficiency of the chiller system. The findings and recommendations on how to optimize chiller systems for best energy performance will also be presented.

Key concepts: Chiller, Chilled water, Condenser (optics), Water chiller, Gas compressor, Chiller boiler system, Cooling capacity, Coefficient of performance

Related papers

Back to paper searchBrowse research topicsOriginal source
The Effect of Chilled Water Supply Temperature on the Energy Efficiency of the Chiller System — Research Paper | ScholarLens