2000Unpublished venueRequires access

Preliminary tests of an X-ray Michelson interferometer

U. Kuetgens, G. Materlik, A. M. Rostomyan, Alex Manoogian

Open publisher page 0 citations

Abstract

A Michelson interferometer has been proposed as a diagnostic tool for measuring the longitudinal coherence of X-rays from seeded FEL undulators [1]. In the authors’ contribution to last year’s HASYLAB Annual Report [2], a design for an X-ray Michelson interferometer was described and the earliest successful test of it was shown. The Michelson interferometer is based on the BBB interferometer of Bonse and Hart [3]. It is built into a single silicon crystal into which an LLL interferometer [4] was also cut. One of the BBB interferometer’s mirrors is connected to the rest of the crystal through a set of flexure joints, so that a piezo pressed against it can displace it perpendicular to the other components of the BBB and so introduce a path difference. At the end of the article, two tasks were set forth: the continued examination of the interferometer with brighter sources than the bending magnet ROMO-1, and the development of a piezo system capable of introducing the necessary displacement in the movable mirror. The past year’s results in both these tasks will be outlined here.

About this research paper

What this paper is about

A Michelson interferometer has been proposed as a diagnostic tool for measuring the longitudinal coherence of X-rays from seeded FEL undulators [1]. In the authors’ contribution to last year’s HASYLAB Annual Report [2], a design for an X-ray Michelson interferometer was described and the earliest successful test of it was shown. The Michelson interferometer is based on the BBB interferometer of Bonse and Hart [3]. It is built into a single silicon crystal into which an LLL interferometer [4] was also cut. One of the BBB interferometer’s mirrors is connected to the rest of the crystal through a set of flexure joints, so that a piezo pressed against it can displace it perpendicular to the other components of the BBB and so introduce a path difference. At the end of the article, two tasks were set forth: the continued examination of the interferometer with brighter sources than the bending magnet ROMO-1, and the development of a piezo system capable of introducing the necessary displacement in the movable mirror. The past year’s results in both these tasks will be outlined here.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A Michelson interferometer has been proposed as a diagnostic tool for measuring the longitudinal coherence of X-rays from seeded FEL undulators [1]. In the authors’ contribution to last year’s HASYLAB Annual Report [2], a design for an X-ray Michelson interferometer was described and the earliest successful test of it was shown. The Michelson interferometer is based on the BBB interferometer of Bonse and Hart [3]. It is built into a single silicon crystal into which an LLL interferometer [4] was also cut. One of the BBB interferometer’s mirrors is connected to the rest of the crystal through a set of flexure joints, so that a piezo pressed against it can displace it perpendicular to the other components of the BBB and so introduce a path difference. At the end of the article, two tasks were set forth: the continued examination of the interferometer with brighter sources than the bending magnet ROMO-1, and the development of a piezo system capable of introducing the necessary displacement in the movable mirror. The past year’s results in both these tasks will be outlined here.

Key concepts: Michelson interferometer, Interferometry, Optics, Physics, Astronomical interferometer, Intensity interferometer, Interferometric visibility, Displacement (psychology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Preliminary tests of an X-ray Michelson interferometer — Research Paper | ScholarLens