Elastic moduli of collagen fibrils measured by nanoindentation test using atomic force microscope (AFM) and tensile test
Noritaka Yamamoto, Shintaro Yabe
Abstract
Open-access reader
Noritaka Yamamoto, Shintaro Yabe
Abstract
Open-access reader
Fibrils were isolated from rat tail tendons and the nanoindentation tests and tensile tests of these fibrils were performed in air (dry condition). In the nanoindentation test using atomic force microscope (AFM), the indentation depth and force of the AFM tip were determined by the force curve measurement. Elastic modulus was calculated from these data using Hertzian contact theory. In the tensile test, the both ends of the fibril were wound on to the tips of microneedles and the fibril was stretched to failure by moving the microneedle under dark-field observation. Elastic modulus was determined as the slope of the approximate line of the measured stress-strain relation. Elastic moduli measured by the nanoindentation tests and tensile tests were 0.97 ± 0.55 GPa and 0.90 ± 0.39 GPa (Mean ± S.D.), respectively. There was no significant difference between the two values. These results indicate that the elastic modulus of the sub-fibrils in the surface layers of fibrils may not be significantly different from that of whole fibrils in the longitudinal direction.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Fibrils were isolated from rat tail tendons and the nanoindentation tests and tensile tests of these fibrils were performed in air (dry condition). In the nanoindentation test using atomic force microscope (AFM), the indentation depth and force of the AFM tip were determined by the force curve measurement. Elastic modulus was calculated from these data using Hertzian contact theory. In the tensile test, the both ends of the fibril were wound on to the tips of microneedles and the fibril was stretched to failure by moving the microneedle under dark-field observation. Elastic modulus was determined as the slope of the approximate line of the measured stress-strain relation. Elastic moduli measured by the nanoindentation tests and tensile tests were 0.97 ± 0.55 GPa and 0.90 ± 0.39 GPa (Mean ± S.D.), respectively. There was no significant difference between the two values. These results indicate that the elastic modulus of the sub-fibrils in the surface layers of fibrils may not be significantly different from that of whole fibrils in the longitudinal direction.
Key concepts: Nanoindentation, Materials science, Indentation, Elastic modulus, Composite material, Tensile testing, Atomic force microscopy, Ultimate tensile strength