Parabolic reflection high intensity ultrasound based device with mechanically-variable focusing
Vesna Zderic, Brooks A. Miller, A. Shahrazad, Simon Bailey, Shahram Vaezy
Abstract
Vesna Zderic, Brooks A. Miller, A. Shahrazad, Simon Bailey, Shahram Vaezy
Abstract
The goal of our investigation is to develop a high intensity focused ultrasound (HIFU) device with mechanically-variable focal lengths, achieved by parabolic reflection mechanism. Several configurations of parabolic reflector were simulated using Wave2000 Pro and a custom-developed geometric ray tracing method (MatLab). A cylindrical ultrasound transducer (height 5 cm, diameter 3.7 cm, frequency 2 MHz) was used as the source. Translational and rotational movements of single parabolic reflectors, multiple parabolic reflectors, and segmented parabolic reflectors were considered for their effectiveness in focusing the beam in the range of 5-10 cm. The simulations showed that focusing using a single parabola was achieved with a translation of 14 cm, and a rotation of 25 /spl deg/. Multiple parabola provided optimal focusing with a minimum number of 4 segments. Parabolic reflection mechanism may provide an effective method of a variable-focus HIFU transducer.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The goal of our investigation is to develop a high intensity focused ultrasound (HIFU) device with mechanically-variable focal lengths, achieved by parabolic reflection mechanism. Several configurations of parabolic reflector were simulated using Wave2000 Pro and a custom-developed geometric ray tracing method (MatLab). A cylindrical ultrasound transducer (height 5 cm, diameter 3.7 cm, frequency 2 MHz) was used as the source. Translational and rotational movements of single parabolic reflectors, multiple parabolic reflectors, and segmented parabolic reflectors were considered for their effectiveness in focusing the beam in the range of 5-10 cm. The simulations showed that focusing using a single parabola was achieved with a translation of 14 cm, and a rotation of 25 /spl deg/. Multiple parabola provided optimal focusing with a minimum number of 4 segments. Parabolic reflection mechanism may provide an effective method of a variable-focus HIFU transducer.
Key concepts: Parabola, Parabolic reflector, Optics, Reflector (photography), Ray tracing (physics), Reflection (computer programming), Rotation (mathematics), Transducer