2012•Unpublished venueRequires access

Impulse noise influence on communication system in high-voltage substation

Zijad Bajramović, Irfan Turković, Aleksandar Mastilovic, Adnan Mujezinović

Open publisher page 0 citations

Abstract

In real high voltage systems, it is necessary to observe system parameters. Depend on investigated values, it is possible to detect malfunctions or overvoltage in high-voltage substation. Because of these, communication system in actual high voltage substation is implemented. In the high-voltage substation disconnector and circuit breaker are installed, whose operation causing appearance of impulse noise effect in the present communication system. Disconnector's contacts in air-insulated substations (AIS) are moving slowly causing numerous strikes and re-strikes between contacts. Every strike causes high-frequency currents (from a few hundred kHz to a few MHz) tending to equalize potentials at the contacts. These processes are the source of impulse noise in the connected communication system. In this paper measured impulse noise level and estimate influence to probability of false alarm appearance in the communication system are presented.

About this research paper

What this paper is about

In real high voltage systems, it is necessary to observe system parameters. Depend on investigated values, it is possible to detect malfunctions or overvoltage in high-voltage substation. Because of these, communication system in actual high voltage substation is implemented. In the high-voltage substation disconnector and circuit breaker are installed, whose operation causing appearance of impulse noise effect in the present communication system. Disconnector's contacts in air-insulated substations (AIS) are moving slowly causing numerous strikes and re-strikes between contacts. Every strike causes high-frequency currents (from a few hundred kHz to a few MHz) tending to equalize potentials at the contacts. These processes are the source of impulse noise in the connected communication system. In this paper measured impulse noise level and estimate influence to probability of false alarm appearance in the communication system are presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In real high voltage systems, it is necessary to observe system parameters. Depend on investigated values, it is possible to detect malfunctions or overvoltage in high-voltage substation. Because of these, communication system in actual high voltage substation is implemented. In the high-voltage substation disconnector and circuit breaker are installed, whose operation causing appearance of impulse noise effect in the present communication system. Disconnector's contacts in air-insulated substations (AIS) are moving slowly causing numerous strikes and re-strikes between contacts. Every strike causes high-frequency currents (from a few hundred kHz to a few MHz) tending to equalize potentials at the contacts. These processes are the source of impulse noise in the connected communication system. In this paper measured impulse noise level and estimate influence to probability of false alarm appearance in the communication system are presented.

Key concepts: Disconnector, Overvoltage, Impulse (physics), Impulse noise, Electrical engineering, Voltage, Circuit breaker, High voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Impulse noise influence on communication system in high-voltage substation — Research Paper | ScholarLens