2011Unpublished venueRequires access

Development of thermal neutron flux monitor using small scintillator array coupled with quartz fibers for Boron Neutron Capture Therapy

Hiroki Tanaka, Yoshinori Sakurai, Minoru Suzuki, Shin‐ichiro Masunaga, Yuko Kinashi, Natsuko Kondo, Yuji Kawabata, Takahiro Yagi, Tsuyoshi Misawa, Koji Ono, Akira Maruhashi

Open publisher page 0 citations

Abstract

At Kyoto University Research Reactor Institute, over three hundred clinical trials of Boron Neutron Capture Therapy (BNCT) have been performed using research reactor. On the other hand, we have developed cyclotron based epithermal neutron source. To improve the quality of treatment, it is necessary to perform the detection of two dimensional thermal neutron distribution before treatment as quality control. Generally, the method of activation using gold foil/wire and germanium semiconductor detector is applied to detection of thermal neutron flux at several positions. However, the activation method using semiconductor detector takes some time to decide the thermal neutron flux. Therefore, we propose the method using small scintillator arrays coupled with quartz fibers for easy detection of two dimensional thermal neutron distribution with low radiation damage. To reduce the number of electric circuit and scintillators, we proposed the scanning method using one dimensional scintillation array. To evaluate this method, the irradiation test was performed using Kyoto University Research Reactor(KUR). Two dimensional thermal neutron distribution was easily obtained with the spatial resolution of 5mm.

About this research paper

What this paper is about

At Kyoto University Research Reactor Institute, over three hundred clinical trials of Boron Neutron Capture Therapy (BNCT) have been performed using research reactor. On the other hand, we have developed cyclotron based epithermal neutron source. To improve the quality of treatment, it is necessary to perform the detection of two dimensional thermal neutron distribution before treatment as quality control. Generally, the method of activation using gold foil/wire and germanium semiconductor detector is applied to detection of thermal neutron flux at several positions. However, the activation method using semiconductor detector takes some time to decide the thermal neutron flux. Therefore, we propose the method using small scintillator arrays coupled with quartz fibers for easy detection of two dimensional thermal neutron distribution with low radiation damage. To reduce the number of electric circuit and scintillators, we proposed the scanning method using one dimensional scintillation array. To evaluate this method, the irradiation test was performed using Kyoto University Research Reactor(KUR). Two dimensional thermal neutron distribution was easily obtained with the spatial resolution of 5mm.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At Kyoto University Research Reactor Institute, over three hundred clinical trials of Boron Neutron Capture Therapy (BNCT) have been performed using research reactor. On the other hand, we have developed cyclotron based epithermal neutron source. To improve the quality of treatment, it is necessary to perform the detection of two dimensional thermal neutron distribution before treatment as quality control. Generally, the method of activation using gold foil/wire and germanium semiconductor detector is applied to detection of thermal neutron flux at several positions. However, the activation method using semiconductor detector takes some time to decide the thermal neutron flux. Therefore, we propose the method using small scintillator arrays coupled with quartz fibers for easy detection of two dimensional thermal neutron distribution with low radiation damage. To reduce the number of electric circuit and scintillators, we proposed the scanning method using one dimensional scintillation array. To evaluate this method, the irradiation test was performed using Kyoto University Research Reactor(KUR). Two dimensional thermal neutron distribution was easily obtained with the spatial resolution of 5mm.

Key concepts: Neutron detection, Neutron temperature, Scintillator, Neutron flux, Materials science, Neutron capture, Neutron, Neutron cross section

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of thermal neutron flux monitor using small scintillator array coupled with quartz fibers for Boron Neutron Capture Therapy — Research Paper | ScholarLens