2003IEEE PES Transmission and Distribution Conference and ExhibitionRequires access

Frequency spectrum analysis of fast transient currents (FTC) due to switching operations in a 245 kV GIS

Mandava Mohana Rao, M. Joy Thomas, B.P. Singh

Open publisher page 7 citations

Abstract

In a gas insulated substation (GIS), very fast transient overvoltages (VFTO) are generated, due to switching operations. These transient overvoltages and the associated fast transient currents (FTC) develop transient electromagnetic (EM) fields during its propagation through HT conductor of GIS. The transient EM fields due to these transient voltages/currents may leak out into external environment through discontinuities like SF/sub 6/ to air bushing, SF/sub 6/ to cable termination, non-metallic viewing ports, insulated flanges, CT, CVT etc. The conducted/induced voltages on control cables/control circuit due to transient EM fields depend on its frequency components. The frequency components and amplitude of transient voltages/currents during switching operations dictate the frequency components and amplitude of transient fields respectively for a particular GIS configuration. In the present paper, the effect of switching operation on peak magnitude of transient currents and their dominant frequency components at different positions in a 245 kV GIS have been reported.

About this research paper

What this paper is about

In a gas insulated substation (GIS), very fast transient overvoltages (VFTO) are generated, due to switching operations. These transient overvoltages and the associated fast transient currents (FTC) develop transient electromagnetic (EM) fields during its propagation through HT conductor of GIS. The transient EM fields due to these transient voltages/currents may leak out into external environment through discontinuities like SF/sub 6/ to air bushing, SF/sub 6/ to cable termination, non-metallic viewing ports, insulated flanges, CT, CVT etc. The conducted/induced voltages on control cables/control circuit due to transient EM fields depend on its frequency components. The frequency components and amplitude of transient voltages/currents during switching operations dictate the frequency components and amplitude of transient fields respectively for a particular GIS configuration. In the present paper, the effect of switching operation on peak magnitude of transient currents and their dominant frequency components at different positions in a 245 kV GIS have been reported.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In a gas insulated substation (GIS), very fast transient overvoltages (VFTO) are generated, due to switching operations. These transient overvoltages and the associated fast transient currents (FTC) develop transient electromagnetic (EM) fields during its propagation through HT conductor of GIS. The transient EM fields due to these transient voltages/currents may leak out into external environment through discontinuities like SF/sub 6/ to air bushing, SF/sub 6/ to cable termination, non-metallic viewing ports, insulated flanges, CT, CVT etc. The conducted/induced voltages on control cables/control circuit due to transient EM fields depend on its frequency components. The frequency components and amplitude of transient voltages/currents during switching operations dictate the frequency components and amplitude of transient fields respectively for a particular GIS configuration. In the present paper, the effect of switching operation on peak magnitude of transient currents and their dominant frequency components at different positions in a 245 kV GIS have been reported.

Key concepts: Transient (computer programming), Bushing, Overvoltage, Voltage, Electrical engineering, Amplitude, Transient voltage suppressor, Transient response

Related papers

Back to paper searchBrowse research topicsOriginal source
Frequency spectrum analysis of fast transient currents (FTC) due to switching operations in a 245 kV GIS — Research Paper | ScholarLens