Multi-area frequency and tie-line power flow control by coordinated AGC with TCPS

M.R.I. Sheikh, Rion Takahashi, Junji Tamura

Open publisher page 7 citations

Abstract

Frequency deviations and inter-area tie-power fluctuations from their respective scheduled values following a local load disturbance are a source of great concern in interconnected power system operation and control. In this paper, a new method is proposed to minimize such deviations and thereby enhance the performance of Automatic Generation Control (AGC) of an interconnected power system. In which, the coordinated operation of a Thyristor-Controlled-Phase-Shifter (TCPS), in an area and in series with the tie-line with Fuzzy Gain Scheduled (FGS) supplementary controller is proposed for the improvement of Load Frequency Control (LFC). Finally, the performances of the Gain Scheduled AGC-TCPS combination are also compared with that of optimized fixed gain (OFG) AGC-TCPS combination. The simulation results show that the FGS-AGC with TCPS performs more effective primary frequency control compared to OFG-AGC with TCPS.

About this research paper

What this paper is about

Frequency deviations and inter-area tie-power fluctuations from their respective scheduled values following a local load disturbance are a source of great concern in interconnected power system operation and control. In this paper, a new method is proposed to minimize such deviations and thereby enhance the performance of Automatic Generation Control (AGC) of an interconnected power system. In which, the coordinated operation of a Thyristor-Controlled-Phase-Shifter (TCPS), in an area and in series with the tie-line with Fuzzy Gain Scheduled (FGS) supplementary controller is proposed for the improvement of Load Frequency Control (LFC). Finally, the performances of the Gain Scheduled AGC-TCPS combination are also compared with that of optimized fixed gain (OFG) AGC-TCPS combination. The simulation results show that the FGS-AGC with TCPS performs more effective primary frequency control compared to OFG-AGC with TCPS.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Frequency deviations and inter-area tie-power fluctuations from their respective scheduled values following a local load disturbance are a source of great concern in interconnected power system operation and control. In this paper, a new method is proposed to minimize such deviations and thereby enhance the performance of Automatic Generation Control (AGC) of an interconnected power system. In which, the coordinated operation of a Thyristor-Controlled-Phase-Shifter (TCPS), in an area and in series with the tie-line with Fuzzy Gain Scheduled (FGS) supplementary controller is proposed for the improvement of Load Frequency Control (LFC). Finally, the performances of the Gain Scheduled AGC-TCPS combination are also compared with that of optimized fixed gain (OFG) AGC-TCPS combination. The simulation results show that the FGS-AGC with TCPS performs more effective primary frequency control compared to OFG-AGC with TCPS.

Key concepts: Automatic Generation Control, Automatic frequency control, Automatic gain control, Tie line, Control theory (sociology), Frequency deviation, Engineering, Controller (irrigation)