2007•International Power Engineering ConferenceRequires access

Surge arrester requirements study for transformer protection in 132 kV GIS substation

Zulkurnain Abdul‐Malek

Open publisher page 1 citations

Abstract

Insulation coordination study for a substation requires accurate prediction of possible overvoltages generated within or external to the substation. Protective devices in the form of surge arresters are usually installed to protect substation equipment from overvoltages caused by both switching and lightning surges. In this work, the decision whether to install or not to install ZnO surge arresters for power transformer protection in a 132 kV GIS substation was made with the aid of ATP-EMTP software. Various models such as those for underground cables and ZnO surge arresters were carefully studied since the results of the simulation study were very much dependent on the models chosen. The resulting overvoltages at the power transformer due to possible lightning impulses at various injections points were studied. A decision was finally made based on the simulation results.

About this research paper

What this paper is about

Insulation coordination study for a substation requires accurate prediction of possible overvoltages generated within or external to the substation. Protective devices in the form of surge arresters are usually installed to protect substation equipment from overvoltages caused by both switching and lightning surges. In this work, the decision whether to install or not to install ZnO surge arresters for power transformer protection in a 132 kV GIS substation was made with the aid of ATP-EMTP software. Various models such as those for underground cables and ZnO surge arresters were carefully studied since the results of the simulation study were very much dependent on the models chosen. The resulting overvoltages at the power transformer due to possible lightning impulses at various injections points were studied. A decision was finally made based on the simulation results.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Insulation coordination study for a substation requires accurate prediction of possible overvoltages generated within or external to the substation. Protective devices in the form of surge arresters are usually installed to protect substation equipment from overvoltages caused by both switching and lightning surges. In this work, the decision whether to install or not to install ZnO surge arresters for power transformer protection in a 132 kV GIS substation was made with the aid of ATP-EMTP software. Various models such as those for underground cables and ZnO surge arresters were carefully studied since the results of the simulation study were very much dependent on the models chosen. The resulting overvoltages at the power transformer due to possible lightning impulses at various injections points were studied. A decision was finally made based on the simulation results.

Key concepts: Surge arrester, Lightning arrester, Transformer, Overvoltage, Emtp, Surge, Engineering, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Surge arrester requirements study for transformer protection in 132 kV GIS substation — Research Paper | ScholarLens