Improvement of Transient Response of Thermal Power Plant Using VVVF Inverter
Nobumasa Matsui, Fujio Kurokawa
Abstract
Nobumasa Matsui, Fujio Kurokawa
Abstract
The construction of a thermal power plant is relatively little. However, the thermal power plant holds approximately 65% of world power source. Recently, the concern with the request of improvement for deterioration in the efficiency has been growing in the existing thermal power plant. Especially, it is required the efficiency for a small thermal power plant that is operated in the partial load. An inverter power source is applied to the field of various power electronics for the energy saving. When the inverter power source occurs abnormally, what is at stake is time delay in the transient response of air flow controller to the heating balance of the boiler and NOXof environment factor. Therefore, the purpose of this paper is to present a new air flow control to improve of transient response in partial load for safety operation in the boiler when the inverter of forced draft fan is occurred abnormally. As a result, the combustion remained gas oxygen is back to original condition less than 1.0 second in the all case.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The construction of a thermal power plant is relatively little. However, the thermal power plant holds approximately 65% of world power source. Recently, the concern with the request of improvement for deterioration in the efficiency has been growing in the existing thermal power plant. Especially, it is required the efficiency for a small thermal power plant that is operated in the partial load. An inverter power source is applied to the field of various power electronics for the energy saving. When the inverter power source occurs abnormally, what is at stake is time delay in the transient response of air flow controller to the heating balance of the boiler and NOXof environment factor. Therefore, the purpose of this paper is to present a new air flow control to improve of transient response in partial load for safety operation in the boiler when the inverter of forced draft fan is occurred abnormally. As a result, the combustion remained gas oxygen is back to original condition less than 1.0 second in the all case.
Key concepts: Boiler (water heating), Inverter, Transient (computer programming), Power station, Thermal power station, Automotive engineering, Electrical engineering, Combustion