2015Journal of The Electrochemical SocietyOpen access

Comparisons of Spray Characteristics Depending on the Nozzle Parameters in a Wafer Cleaning System Using a Twin-Fluid Nozzle

Jun-Kyu Park, Jongbin Kang, Sungwook Park

Open full text 3 citations

Abstract

This study was performed to investigate how the nozzle design parameters affect the spray characteristics of a twin-fluid nozzle used in wafer cleaning. External mixing-type twin-fluid nozzles, which had various design parameters that could be changed, were used to understand the effects of each parameter. Deionized water (DIW) and N2 gas were used as the working fluids. Various design parameters of the twin-fluid nozzle, such as the liquid nozzle diameter, gas slit angle, and the number of nozzles, critically affected the spray behavior in terms of both the macroscopic and microscopic spray characteristics. Measurements were made using a Nd:YAG laser and an ICCD camera. Additionally, the droplet size and velocity were determined using a phase Doppler particle analyzer (PDPA) in order to optimize the microscopic spray characteristics in terms of the spatial distribution and Sauter mean diameter (SMD). Experimental results show that the macroscopic spray characteristics did not change significantly as the gas slit angle was altered; however, the microscopic spray behaviors (e.g., the droplet diameter and mean velocity) were distinctly varied. By identifying the effects of independent design parameters, it appears that wafer the cleaning performance can be improved.

Open-access reader

About this research paper

What this paper is about

This study was performed to investigate how the nozzle design parameters affect the spray characteristics of a twin-fluid nozzle used in wafer cleaning. External mixing-type twin-fluid nozzles, which had various design parameters that could be changed, were used to understand the effects of each parameter. Deionized water (DIW) and N2 gas were used as the working fluids. Various design parameters of the twin-fluid nozzle, such as the liquid nozzle diameter, gas slit angle, and the number of nozzles, critically affected the spray behavior in terms of both the macroscopic and microscopic spray characteristics. Measurements were made using a Nd:YAG laser and an ICCD camera. Additionally, the droplet size and velocity were determined using a phase Doppler particle analyzer (PDPA) in order to optimize the microscopic spray characteristics in terms of the spatial distribution and Sauter mean diameter (SMD). Experimental results show that the macroscopic spray characteristics did not change significantly as the gas slit angle was altered; however, the microscopic spray behaviors (e.g., the droplet diameter and mean velocity) were distinctly varied. By identifying the effects of independent design parameters, it appears that wafer the cleaning performance can be improved.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study was performed to investigate how the nozzle design parameters affect the spray characteristics of a twin-fluid nozzle used in wafer cleaning. External mixing-type twin-fluid nozzles, which had various design parameters that could be changed, were used to understand the effects of each parameter. Deionized water (DIW) and N2 gas were used as the working fluids. Various design parameters of the twin-fluid nozzle, such as the liquid nozzle diameter, gas slit angle, and the number of nozzles, critically affected the spray behavior in terms of both the macroscopic and microscopic spray characteristics. Measurements were made using a Nd:YAG laser and an ICCD camera. Additionally, the droplet size and velocity were determined using a phase Doppler particle analyzer (PDPA) in order to optimize the microscopic spray characteristics in terms of the spatial distribution and Sauter mean diameter (SMD). Experimental results show that the macroscopic spray characteristics did not change significantly as the gas slit angle was altered; however, the microscopic spray behaviors (e.g., the droplet diameter and mean velocity) were distinctly varied. By identifying the effects of independent design parameters, it appears that wafer the cleaning performance can be improved.

Key concepts: Nozzle, Spray nozzle, Spray characteristics, Sauter mean diameter, Wafer, Materials science, Working fluid, Mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparisons of Spray Characteristics Depending on the Nozzle Parameters in a Wafer Cleaning System Using a Twin-Fluid Nozzle — Research Paper | ScholarLens