Joint Strength of SUS304 Stainless Steel Joint Brazed with Fe-Cr System Alloy
Kangdao Shi, Takahiro Tsunoda, K. Kusumoto, Ikuo Shohji, Kotaro Matsu, Yasuhiro Taguchi
Abstract
Open-access reader
Kangdao Shi, Takahiro Tsunoda, K. Kusumoto, Ikuo Shohji, Kotaro Matsu, Yasuhiro Taguchi
Abstract
Open-access reader
Two kinds of new Fe-Cr system alloy brazing filler, Fe-Cr-based and Fe-based, have been developed as a substitute for expensive Ni-based brazing filler in brazing of SUS304 stainless steel. Joint strength of the joints brazed with new filler were investigated and compared with the joint brazed with Ni-based brazing filler. The following results were obtained in the study. P-rich phases were formed because Ni in the new Fe-Cr system alloy diffused from the brazed layer to SUS304 stainless steel when joint clearance was 10 μm. When joint clearance was more than 50 μm, a finally-solidified region appeared in the brazed layer, at the same time, most of P segregated and was enriched in the finally-solidified region. It was proved that the volume fraction of P-rich phases in the finally-solidified region varied with the increase of joint clearance and joint strength decreases with the increase of the volume fraction of P-rich phases. Compared with Ni-based filler, joint strength of the joint brazed with Fe-based filler was almost equal when joint clearance was under 200 μm. On the other hand, joint strength of the joint brazed with Fe-Cr-based filler was slightly inferior regardless of joint clearance. Still, joint strength reached approximately 100 MPa. The result indicated that joint strength of the brazed joint with the Fe-Cr system alloy was strongly affected by the P addition. It is possible that promoting of joint strength can be brought by lower addition of P.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Two kinds of new Fe-Cr system alloy brazing filler, Fe-Cr-based and Fe-based, have been developed as a substitute for expensive Ni-based brazing filler in brazing of SUS304 stainless steel. Joint strength of the joints brazed with new filler were investigated and compared with the joint brazed with Ni-based brazing filler. The following results were obtained in the study. P-rich phases were formed because Ni in the new Fe-Cr system alloy diffused from the brazed layer to SUS304 stainless steel when joint clearance was 10 μm. When joint clearance was more than 50 μm, a finally-solidified region appeared in the brazed layer, at the same time, most of P segregated and was enriched in the finally-solidified region. It was proved that the volume fraction of P-rich phases in the finally-solidified region varied with the increase of joint clearance and joint strength decreases with the increase of the volume fraction of P-rich phases. Compared with Ni-based filler, joint strength of the joint brazed with Fe-based filler was almost equal when joint clearance was under 200 μm. On the other hand, joint strength of the joint brazed with Fe-Cr-based filler was slightly inferior regardless of joint clearance. Still, joint strength reached approximately 100 MPa. The result indicated that joint strength of the brazed joint with the Fe-Cr system alloy was strongly affected by the P addition. It is possible that promoting of joint strength can be brought by lower addition of P.
Key concepts: Brazing, Materials science, Joint (building), Alloy, Metallurgy, Filler metal, Composite material, Filler (materials)