2016Unpublished venueRequires access

Photoplethysmography: Towards a non-invasive pressure measurement technique

Haneen Njoum, P. A. Kyriacou

Open publisher page 5 citations

Abstract

There is a need for non-invasive and continuous blood pressure measurements. This study explored the relationship between Photoplethysmography (PPG) and Pressure-Volume (P-V) changes in an in vitro model. We proposed and compared methods for an estimation of the pulsatile volume, termed as Normalized Pulse Volume (NPV) and Adjusted Pulse Volume (APV). To validate the methods, pressure, Red (R) and InfraRed (IR) PPG signals were recorded continuously in an arterial model utilizing a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. It was found that the optimum method for estimation of the pulsatile volume is through APV, which had a high correlation (r2=0.99, pIR(r2=0.73, z=25.85, pR(r2=0.95, z=12.26, p<;0.001). These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement.

About this research paper

What this paper is about

There is a need for non-invasive and continuous blood pressure measurements. This study explored the relationship between Photoplethysmography (PPG) and Pressure-Volume (P-V) changes in an in vitro model. We proposed and compared methods for an estimation of the pulsatile volume, termed as Normalized Pulse Volume (NPV) and Adjusted Pulse Volume (APV). To validate the methods, pressure, Red (R) and InfraRed (IR) PPG signals were recorded continuously in an arterial model utilizing a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. It was found that the optimum method for estimation of the pulsatile volume is through APV, which had a high correlation (r2=0.99, pIR(r2=0.73, z=25.85, pR(r2=0.95, z=12.26, p<;0.001). These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There is a need for non-invasive and continuous blood pressure measurements. This study explored the relationship between Photoplethysmography (PPG) and Pressure-Volume (P-V) changes in an in vitro model. We proposed and compared methods for an estimation of the pulsatile volume, termed as Normalized Pulse Volume (NPV) and Adjusted Pulse Volume (APV). To validate the methods, pressure, Red (R) and InfraRed (IR) PPG signals were recorded continuously in an arterial model utilizing a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. It was found that the optimum method for estimation of the pulsatile volume is through APV, which had a high correlation (r2=0.99, pIR(r2=0.73, z=25.85, pR(r2=0.95, z=12.26, p<;0.001). These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement.

Key concepts: Photoplethysmogram, Computer science, Pressure measurement, Engineering, Telecommunications, Wireless, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Photoplethysmography: Towards a non-invasive pressure measurement technique — Research Paper | ScholarLens