2005•Unpublished venueRequires access

Power supply quality improvement: harmonic measurement and simulation

Dalila Mat Said, Nasarudin Ahmad, Abdullah Asuhaimi Mohd Zin

Open publisher page 7 citations

Abstract

This paper presents the harmonic measurement and simulation in a power distribution network and then gives suggestion of filter installation to improve harmonic distortion. The specific case study has been conducted at Faculty of Electrical Engineering, UTM building where nonlinear loads such as computers and fluorescent lamps which produce the harmonics are connected. Measurements are conducted at each subswitch board (SSB), main-switch board (MSB) and substation of the faculty. The selected networks are modelled and simulated using SKM-Power Tools for Windows software. The results from the measurement are compared with the simulation result, and it is found that there are quite close to each other. Based on the simulation, harmonic distortion improved after filter installation.

About this research paper

What this paper is about

This paper presents the harmonic measurement and simulation in a power distribution network and then gives suggestion of filter installation to improve harmonic distortion. The specific case study has been conducted at Faculty of Electrical Engineering, UTM building where nonlinear loads such as computers and fluorescent lamps which produce the harmonics are connected. Measurements are conducted at each subswitch board (SSB), main-switch board (MSB) and substation of the faculty. The selected networks are modelled and simulated using SKM-Power Tools for Windows software. The results from the measurement are compared with the simulation result, and it is found that there are quite close to each other. Based on the simulation, harmonic distortion improved after filter installation.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents the harmonic measurement and simulation in a power distribution network and then gives suggestion of filter installation to improve harmonic distortion. The specific case study has been conducted at Faculty of Electrical Engineering, UTM building where nonlinear loads such as computers and fluorescent lamps which produce the harmonics are connected. Measurements are conducted at each subswitch board (SSB), main-switch board (MSB) and substation of the faculty. The selected networks are modelled and simulated using SKM-Power Tools for Windows software. The results from the measurement are compared with the simulation result, and it is found that there are quite close to each other. Based on the simulation, harmonic distortion improved after filter installation.

Key concepts: Harmonics, Total harmonic distortion, Distortion (music), Harmonic, Power (physics), Electronic engineering, Harmonic analysis, Nonlinear distortion

Related papers

Back to paper searchBrowse research topicsOriginal source
Power supply quality improvement: harmonic measurement and simulation — Research Paper | ScholarLens