2011Unpublished venueRequires access

Retrofit design of heat exchanger network (HEN) on Synthesis and Purification Unit of methanol plant

Siti Rafidah Ab Rashid, Ummi Kalthum Ibrahim, Sakinah Mohd Alauddin

Open publisher page 5 citations

Abstract

Due to the current worldwide energy and economic crisis, all possible options of reducing the energy consumption are explored. This drives chemical processing plant as one of the energy-intensive consumers to strive for energy efficiency projects such as retrofitting the heat exchanger network (HEN). The retrofit project is focusing on the reduction of heat consumption in the plant to its minimum energy requirement (MER). As a result of this, the plant energy efficiency will increase tremendously. In this work, pinch technology is exploited in analysing the potential energy saving and economic gain. As a case study of the work, a typical methanol plant is considered. The pinch calculation shows the potential energy saving is 48,417 kW. This amount of energy accounts 74% and 57% of the current hot and cold utility consumptions. This indicates the high potential of attaining the economic gain. The violation of one of the pinch technology rule which is no cooling above the pinch is the reason of the excessive use of the utilities. In the analysis, there are two coolers situated above the pinch and four heat exchangers have low area efficiencies. Therefore, the plant heat exchanger network is retrofitted by modifying a minimum number of network structures and heat exchanger modifications. Minimal modifications are ensured to achieve economic feasibility. This is showed in the economic analysis which it gives the payback period of the investment by 0.4 years.

About this research paper

What this paper is about

Due to the current worldwide energy and economic crisis, all possible options of reducing the energy consumption are explored. This drives chemical processing plant as one of the energy-intensive consumers to strive for energy efficiency projects such as retrofitting the heat exchanger network (HEN). The retrofit project is focusing on the reduction of heat consumption in the plant to its minimum energy requirement (MER). As a result of this, the plant energy efficiency will increase tremendously. In this work, pinch technology is exploited in analysing the potential energy saving and economic gain. As a case study of the work, a typical methanol plant is considered. The pinch calculation shows the potential energy saving is 48,417 kW. This amount of energy accounts 74% and 57% of the current hot and cold utility consumptions. This indicates the high potential of attaining the economic gain. The violation of one of the pinch technology rule which is no cooling above the pinch is the reason of the excessive use of the utilities. In the analysis, there are two coolers situated above the pinch and four heat exchangers have low area efficiencies. Therefore, the plant heat exchanger network is retrofitted by modifying a minimum number of network structures and heat exchanger modifications. Minimal modifications are ensured to achieve economic feasibility. This is showed in the economic analysis which it gives the payback period of the investment by 0.4 years.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Due to the current worldwide energy and economic crisis, all possible options of reducing the energy consumption are explored. This drives chemical processing plant as one of the energy-intensive consumers to strive for energy efficiency projects such as retrofitting the heat exchanger network (HEN). The retrofit project is focusing on the reduction of heat consumption in the plant to its minimum energy requirement (MER). As a result of this, the plant energy efficiency will increase tremendously. In this work, pinch technology is exploited in analysing the potential energy saving and economic gain. As a case study of the work, a typical methanol plant is considered. The pinch calculation shows the potential energy saving is 48,417 kW. This amount of energy accounts 74% and 57% of the current hot and cold utility consumptions. This indicates the high potential of attaining the economic gain. The violation of one of the pinch technology rule which is no cooling above the pinch is the reason of the excessive use of the utilities. In the analysis, there are two coolers situated above the pinch and four heat exchangers have low area efficiencies. Therefore, the plant heat exchanger network is retrofitted by modifying a minimum number of network structures and heat exchanger modifications. Minimal modifications are ensured to achieve economic feasibility. This is showed in the economic analysis which it gives the payback period of the investment by 0.4 years.

Key concepts: Retrofitting, Pinch analysis, Heat exchanger, Process engineering, Payback period, Work (physics), Energy consumption, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Retrofit design of heat exchanger network (HEN) on Synthesis and Purification Unit of methanol plant — Research Paper | ScholarLens