2016IOP Conference Series Materials Science and EngineeringOpen access

A Case Study of a Low Power Vapour Adsorption Refrigeration System

Banala Dinesh, M. Sai Manikanta, T. Dishal Kumar, Debjyoti Sahu

Open full text 6 citations

Abstract

Industrial refrigeration is one of the most energy consuming sector. In conventional Vapor Compression refrigeration system, compressor is the major power consuming element. Vapor Adsorption refrigeration system is one of the best replacement for the Vapor Compression refrigeration system. Our main objective is to analyze, design and develop a Vapor Adsorption refrigeration system which is cost effective and environmental friendly. A prototype model that is capable of producing a temperature drop in closed evaporator chamber was designed, fabricated and tested. Activated carbon/Methanol pair is chosen as Adsorbent/Refrigerant pair. The system is analyzed in ANSYS 14.5 using the inlet conditions obtained from the experimental setup. The performances and effectiveness of the unit was studied by determining Refrigeration Effect (RE), Coefficient of Performance (COP) and explaining operational issues of the unit. The results obtained from the analysis and experiments have marginal difference in COP i.e. with an error percentage of 5.94%. The overall COP obtained is 0.34 through experiments and from analysis the COP obtained is approximately 0.32.

Open-access reader

About this research paper

What this paper is about

Industrial refrigeration is one of the most energy consuming sector. In conventional Vapor Compression refrigeration system, compressor is the major power consuming element. Vapor Adsorption refrigeration system is one of the best replacement for the Vapor Compression refrigeration system. Our main objective is to analyze, design and develop a Vapor Adsorption refrigeration system which is cost effective and environmental friendly. A prototype model that is capable of producing a temperature drop in closed evaporator chamber was designed, fabricated and tested. Activated carbon/Methanol pair is chosen as Adsorbent/Refrigerant pair. The system is analyzed in ANSYS 14.5 using the inlet conditions obtained from the experimental setup. The performances and effectiveness of the unit was studied by determining Refrigeration Effect (RE), Coefficient of Performance (COP) and explaining operational issues of the unit. The results obtained from the analysis and experiments have marginal difference in COP i.e. with an error percentage of 5.94%. The overall COP obtained is 0.34 through experiments and from analysis the COP obtained is approximately 0.32.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Industrial refrigeration is one of the most energy consuming sector. In conventional Vapor Compression refrigeration system, compressor is the major power consuming element. Vapor Adsorption refrigeration system is one of the best replacement for the Vapor Compression refrigeration system. Our main objective is to analyze, design and develop a Vapor Adsorption refrigeration system which is cost effective and environmental friendly. A prototype model that is capable of producing a temperature drop in closed evaporator chamber was designed, fabricated and tested. Activated carbon/Methanol pair is chosen as Adsorbent/Refrigerant pair. The system is analyzed in ANSYS 14.5 using the inlet conditions obtained from the experimental setup. The performances and effectiveness of the unit was studied by determining Refrigeration Effect (RE), Coefficient of Performance (COP) and explaining operational issues of the unit. The results obtained from the analysis and experiments have marginal difference in COP i.e. with an error percentage of 5.94%. The overall COP obtained is 0.34 through experiments and from analysis the COP obtained is approximately 0.32.

Key concepts: Vapor-compression refrigeration, Refrigeration, Coefficient of performance, Refrigerant, Gas compressor, Evaporator, Thermal expansion valve, Nuclear engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A Case Study of a Low Power Vapour Adsorption Refrigeration System — Research Paper | ScholarLens