2016•SpringerPlusOpen access

Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during prone position

Öznur Şen, Mefkür Bakan, Tarık Umutoğlu, Nurdan Aydın, Mehmet Toptaş, İbrahim Akkoç

Open full text 16 citations

Abstract

Prone position during general anesthesia for special surgical operations may be related with increased airway pressure, decreased pulmonary and thoracic compliance that may be explained by restriction of chest expansion and compression of abdomen. The optimum ventilation mode for anesthetized patients on prone position was not described and studies comparing volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) during prone position are limited. We hypothesized that PCV instead of VCV during prone position could achieve lower airway pressures and reduce the systemic stress response. In this study, we aimed to compare the effects of PCV and VCV modes during prone position on respiratory mechanics, oxygenation, and hemodynamics, as well as blood cortisol and insulin levels, which has not been investigated before. Fifty-four ASA I-II patients, 18–70 years of age, who underwent percutaneous nephrolithotomy on prone position, were randomly selected to receive either the PCV (Group PC, n = 27) or VCV (Group VC, n = 27) under general anesthesia with sevoflurane and fentanyl. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH 2 O PEEP. Respiratory parameters were recorded during supine and prone position. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated during surgery and 60 min after extubation. P-peak and P-plateau levels during supine and prone positions were significantly higher and P-mean and compliance levels during prone position were significantly lower in Group VC when compared with Group PC. Postoperative PaO 2 level was significantly higher in Group PC compared with Group VC. Cortisol levels were increased with surgery in both groups (p < 0.05) and decreased to baseline levels in Group PC while remained high in Group VC in the early postoperative period. Cortisol levels were significantly higher in Group VC during surgery and in the early postoperative period compared with Group PC. When compared with VCV mode, PCV mode is associated with lower P-peak and P-plateau levels during both supine and prone positions, better oxygenation postoperatively, lower blood cortisol levels during surgery in prone position and in the early postoperative period. We concluded that PCV mode might be more appropriate in prone position during anesthesia.

Open-access reader

About this research paper

What this paper is about

Prone position during general anesthesia for special surgical operations may be related with increased airway pressure, decreased pulmonary and thoracic compliance that may be explained by restriction of chest expansion and compression of abdomen. The optimum ventilation mode for anesthetized patients on prone position was not described and studies comparing volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) during prone position are limited. We hypothesized that PCV instead of VCV during prone position could achieve lower airway pressures and reduce the systemic stress response. In this study, we aimed to compare the effects of PCV and VCV modes during prone position on respiratory mechanics, oxygenation, and hemodynamics, as well as blood cortisol and insulin levels, which has not been investigated before. Fifty-four ASA I-II patients, 18–70 years of age, who underwent percutaneous nephrolithotomy on prone position, were randomly selected to receive either the PCV (Group PC, n = 27) or VCV (Group VC, n = 27) under general anesthesia with sevoflurane and fentanyl. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH 2 O PEEP. Respiratory parameters were recorded during supine and prone position. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated during surgery and 60 min after extubation. P-peak and P-plateau levels during supine and prone positions were significantly higher and P-mean and compliance levels during prone position were significantly lower in Group VC when compared with Group PC. Postoperative PaO 2 level was significantly higher in Group PC compared with Group VC. Cortisol levels were increased with surgery in both groups (p < 0.05) and decreased to baseline levels in Group PC while remained high in Group VC in the early postoperative period. Cortisol levels were significantly higher in Group VC during surgery and in the early postoperative period compared with Group PC. When compared with VCV mode, PCV mode is associated with lower P-peak and P-plateau levels during both supine and prone positions, better oxygenation postoperatively, lower blood cortisol levels during surgery in prone position and in the early postoperative period. We concluded that PCV mode might be more appropriate in prone position during anesthesia.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Prone position during general anesthesia for special surgical operations may be related with increased airway pressure, decreased pulmonary and thoracic compliance that may be explained by restriction of chest expansion and compression of abdomen. The optimum ventilation mode for anesthetized patients on prone position was not described and studies comparing volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) during prone position are limited. We hypothesized that PCV instead of VCV during prone position could achieve lower airway pressures and reduce the systemic stress response. In this study, we aimed to compare the effects of PCV and VCV modes during prone position on respiratory mechanics, oxygenation, and hemodynamics, as well as blood cortisol and insulin levels, which has not been investigated before. Fifty-four ASA I-II patients, 18–70 years of age, who underwent percutaneous nephrolithotomy on prone position, were randomly selected to receive either the PCV (Group PC, n = 27) or VCV (Group VC, n = 27) under general anesthesia with sevoflurane and fentanyl. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH 2 O PEEP. Respiratory parameters were recorded during supine and prone position. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated during surgery and 60 min after extubation. P-peak and P-plateau levels during supine and prone positions were significantly higher and P-mean and compliance levels during prone position were significantly lower in Group VC when compared with Group PC. Postoperative PaO 2 level was significantly higher in Group PC compared with Group VC. Cortisol levels were increased with surgery in both groups (p < 0.05) and decreased to baseline levels in Group PC while remained high in Group VC in the early postoperative period. Cortisol levels were significantly higher in Group VC during surgery and in the early postoperative period compared with Group PC. When compared with VCV mode, PCV mode is associated with lower P-peak and P-plateau levels during both supine and prone positions, better oxygenation postoperatively, lower blood cortisol levels during surgery in prone position and in the early postoperative period. We concluded that PCV mode might be more appropriate in prone position during anesthesia.

Key concepts: Respiratory physiology, Medicine, Fight-or-flight response, Ventilation (architecture), Respiratory system, Computer science, Intensive care medicine, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during prone position — Research Paper | ScholarLens