2016African Journal of Microbiology ResearchOpen access

Performance of dried blood spot (DBS) PUNCHER and dried blood spots to measure HIV-1 viral load

Dagnra Anoumou, Mounérou Salou, Ehlan Amivi, Konou Ahouefa, Ouro-Medeli Alassane, Dossim Sika, Ali-Edje Komlan

Open full text 0 citations

Abstract

The use of plasma is an obstacle to realize HIV-1 viral load in sub-Saharan Africa. In this context, the dried blood spot (DBS) is an interesting tool for sample collections. This approach was tested using a DBS hole-punch device (PUNCHER). Plasma and DBS samples were obtained from 102 patients, comprising 17 HIV-1 negative patients and 85 HIV-1 infected patients. The PUNCHER’s performance used to cut DBS was evaluated with the following criteria: ease of use, time savings and safety. VL was measured in parallel on plasma and DBS samples using NucliSENS EasyQ HIV-1. The correlation between plasma and DBS results was strong (R = 0.91; P < 0.001). The mean difference (± standard deviation) was -0.59 ± 0.52 log10 copies/ml. The sensitivity and specificity of DBS were 91.3% (n= 74) for the 81 VL detectable samples and 100% for the 21 VL undetectable samples, respectively. On a scale of 10, the PUNCHER’s performance scored 9.3 for ease of use, 8.6 for time savings and 10 for safety. PUNCHER is highly efficient at cutting DBS, and the VL resulting from DBS correlated well with those obtained from plasma. Key words: Puncher, dried blood spot (DBS), viral load, performance.

Open-access reader

About this research paper

What this paper is about

The use of plasma is an obstacle to realize HIV-1 viral load in sub-Saharan Africa. In this context, the dried blood spot (DBS) is an interesting tool for sample collections. This approach was tested using a DBS hole-punch device (PUNCHER). Plasma and DBS samples were obtained from 102 patients, comprising 17 HIV-1 negative patients and 85 HIV-1 infected patients. The PUNCHER’s performance used to cut DBS was evaluated with the following criteria: ease of use, time savings and safety. VL was measured in parallel on plasma and DBS samples using NucliSENS EasyQ HIV-1. The correlation between plasma and DBS results was strong (R = 0.91; P < 0.001). The mean difference (± standard deviation) was -0.59 ± 0.52 log10 copies/ml. The sensitivity and specificity of DBS were 91.3% (n= 74) for the 81 VL detectable samples and 100% for the 21 VL undetectable samples, respectively. On a scale of 10, the PUNCHER’s performance scored 9.3 for ease of use, 8.6 for time savings and 10 for safety. PUNCHER is highly efficient at cutting DBS, and the VL resulting from DBS correlated well with those obtained from plasma. Key words: Puncher, dried blood spot (DBS), viral load, performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of plasma is an obstacle to realize HIV-1 viral load in sub-Saharan Africa. In this context, the dried blood spot (DBS) is an interesting tool for sample collections. This approach was tested using a DBS hole-punch device (PUNCHER). Plasma and DBS samples were obtained from 102 patients, comprising 17 HIV-1 negative patients and 85 HIV-1 infected patients. The PUNCHER’s performance used to cut DBS was evaluated with the following criteria: ease of use, time savings and safety. VL was measured in parallel on plasma and DBS samples using NucliSENS EasyQ HIV-1. The correlation between plasma and DBS results was strong (R = 0.91; P < 0.001). The mean difference (± standard deviation) was -0.59 ± 0.52 log10 copies/ml. The sensitivity and specificity of DBS were 91.3% (n= 74) for the 81 VL detectable samples and 100% for the 21 VL undetectable samples, respectively. On a scale of 10, the PUNCHER’s performance scored 9.3 for ease of use, 8.6 for time savings and 10 for safety. PUNCHER is highly efficient at cutting DBS, and the VL resulting from DBS correlated well with those obtained from plasma. Key words: Puncher, dried blood spot (DBS), viral load, performance.

Key concepts: Dried blood spot, Dried blood, Viral load, Human immunodeficiency virus (HIV), Context (archaeology), Spots, Whole blood, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of dried blood spot (DBS) PUNCHER and dried blood spots to measure HIV-1 viral load — Research Paper | ScholarLens