1987Corrosion engineering digestOpen access

Impedance Characteristics of the Carbon Steel under Cathodic Potential and Determination of an Optimum Protection Potential

Atsushi Nishikata, Baorong Hou, Dae-Hi Jeon, Tooru Tsuru, Shirō Haruyama

Open full text 0 citations

Abstract

It was theoretically shown in a previous paper (1) that ac impedance technique can be successfully utilized for determining and monitoring the optimum cathodic protection potential of the metals in a neutral solution. In this paper, the experimental studies have been made in order to support the theoretical analysis. The potential dependence of the faradaic impedance of carbon steels in 3.5% NaCl solution has been measured by ac impedance technique. The faradaic impedance showed a maximum at -0.70V with respect to sat. Ag/AgCl electrode. The cathodic protection efficiency obtained from weight loss also showed a maximum at the same potential, Therefore, the potential of faradaic impedance maximum corresponds well to the optimum cathodic protection potential, as the theoretical analysis has shown. It was concluded that the ac impedance technique is a promising method for determing as well as monitoring the optimum cathodic protection potential.

Open-access reader

About this research paper

What this paper is about

It was theoretically shown in a previous paper (1) that ac impedance technique can be successfully utilized for determining and monitoring the optimum cathodic protection potential of the metals in a neutral solution. In this paper, the experimental studies have been made in order to support the theoretical analysis. The potential dependence of the faradaic impedance of carbon steels in 3.5% NaCl solution has been measured by ac impedance technique. The faradaic impedance showed a maximum at -0.70V with respect to sat. Ag/AgCl electrode. The cathodic protection efficiency obtained from weight loss also showed a maximum at the same potential, Therefore, the potential of faradaic impedance maximum corresponds well to the optimum cathodic protection potential, as the theoretical analysis has shown. It was concluded that the ac impedance technique is a promising method for determing as well as monitoring the optimum cathodic protection potential.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It was theoretically shown in a previous paper (1) that ac impedance technique can be successfully utilized for determining and monitoring the optimum cathodic protection potential of the metals in a neutral solution. In this paper, the experimental studies have been made in order to support the theoretical analysis. The potential dependence of the faradaic impedance of carbon steels in 3.5% NaCl solution has been measured by ac impedance technique. The faradaic impedance showed a maximum at -0.70V with respect to sat. Ag/AgCl electrode. The cathodic protection efficiency obtained from weight loss also showed a maximum at the same potential, Therefore, the potential of faradaic impedance maximum corresponds well to the optimum cathodic protection potential, as the theoretical analysis has shown. It was concluded that the ac impedance technique is a promising method for determing as well as monitoring the optimum cathodic protection potential.

Key concepts: Cathodic protection, Electrical impedance, Materials science, Faraday efficiency, Carbon steel, Faradaic current, Electrode potential, Electrode

Related papers

Back to paper searchBrowse research topicsOriginal source
Impedance Characteristics of the Carbon Steel under Cathodic Potential and Determination of an Optimum Protection Potential — Research Paper | ScholarLens