2016•Journal of Telemedicine and TelecareOpen access

Asynchronous interpretation of manual and automated audiometry: Agreement and reliability

Christopher G. Brennan‐Jones, Robert Henry Eikelboom, Rebecca Jane Bennett, Karina F. M. Tao, De Wet Swanepoel

Open full text 30 citations

Abstract

Introduction Remote interpretation of automated audiometry offers the potential to enable asynchronous tele-audiology assessment and diagnosis in areas where synchronous tele-audiometry may not be possible or practical. The aim of this study was to compare remote interpretation of manual and automated audiometry. Methods Five audiologists each interpreted manual and automated audiograms obtained from 42 patients. The main outcome variable was the audiologist's recommendation for patient management (which included treatment recommendations, referral or discharge) between the manual and automated audiometry test. Cohen's Kappa and Krippendorff's Alpha were used to calculate and quantify the intra- and inter-observer agreement, respectively, and McNemar's test was used to assess the audiologist-rated accuracy of audiograms. Audiograms were randomised and audiologists were blinded as to whether they were interpreting a manual or automated audiogram. Results Intra-observer agreement was substantial for management outcomes when comparing interpretations for manual and automated audiograms. Inter-observer agreement was moderate between clinicians for determining management decisions when interpreting both manual and automated audiograms. Audiologists were 2.8 times more likely to question the accuracy of an automated audiogram compared to a manual audiogram. Discussion There is a lack of agreement between audiologists when interpreting audiograms, whether recorded with automated or manual audiometry. The main variability in remote audiogram interpretation is likely to be individual clinician variation, rather than automation.

Open-access reader

About this research paper

What this paper is about

Introduction Remote interpretation of automated audiometry offers the potential to enable asynchronous tele-audiology assessment and diagnosis in areas where synchronous tele-audiometry may not be possible or practical. The aim of this study was to compare remote interpretation of manual and automated audiometry. Methods Five audiologists each interpreted manual and automated audiograms obtained from 42 patients. The main outcome variable was the audiologist's recommendation for patient management (which included treatment recommendations, referral or discharge) between the manual and automated audiometry test. Cohen's Kappa and Krippendorff's Alpha were used to calculate and quantify the intra- and inter-observer agreement, respectively, and McNemar's test was used to assess the audiologist-rated accuracy of audiograms. Audiograms were randomised and audiologists were blinded as to whether they were interpreting a manual or automated audiogram. Results Intra-observer agreement was substantial for management outcomes when comparing interpretations for manual and automated audiograms. Inter-observer agreement was moderate between clinicians for determining management decisions when interpreting both manual and automated audiograms. Audiologists were 2.8 times more likely to question the accuracy of an automated audiogram compared to a manual audiogram. Discussion There is a lack of agreement between audiologists when interpreting audiograms, whether recorded with automated or manual audiometry. The main variability in remote audiogram interpretation is likely to be individual clinician variation, rather than automation.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction Remote interpretation of automated audiometry offers the potential to enable asynchronous tele-audiology assessment and diagnosis in areas where synchronous tele-audiometry may not be possible or practical. The aim of this study was to compare remote interpretation of manual and automated audiometry. Methods Five audiologists each interpreted manual and automated audiograms obtained from 42 patients. The main outcome variable was the audiologist's recommendation for patient management (which included treatment recommendations, referral or discharge) between the manual and automated audiometry test. Cohen's Kappa and Krippendorff's Alpha were used to calculate and quantify the intra- and inter-observer agreement, respectively, and McNemar's test was used to assess the audiologist-rated accuracy of audiograms. Audiograms were randomised and audiologists were blinded as to whether they were interpreting a manual or automated audiogram. Results Intra-observer agreement was substantial for management outcomes when comparing interpretations for manual and automated audiograms. Inter-observer agreement was moderate between clinicians for determining management decisions when interpreting both manual and automated audiograms. Audiologists were 2.8 times more likely to question the accuracy of an automated audiogram compared to a manual audiogram. Discussion There is a lack of agreement between audiologists when interpreting audiograms, whether recorded with automated or manual audiometry. The main variability in remote audiogram interpretation is likely to be individual clinician variation, rather than automation.

Key concepts: Audiogram, Audiologist, Audiometry, Audiology, Medicine, Cohen's kappa, McNemar's test, Kappa

Related papers

Back to paper searchBrowse research topicsOriginal source
Asynchronous interpretation of manual and automated audiometry: Agreement and reliability — Research Paper | ScholarLens