2016•Journal of GlaucomaRequires access

Transscleral Selective Laser Trabeculoplasty Without a Gonioscopy Lens

Noa Geffen, Shay Ofir, Avner Belkin, Fani Segev, Yaniv Barkana, Audrey Kaplan Messas, Ehud I. Assia, Michael Belkin

Open publisher page 41 citations

Abstract

PURPOSE OF THE STUDY: The purpose of the study was to investigate results of selective laser trabeculoplasty (SLT) performed directly on the sclera without a gonioscopy lens. DESIGN: Interventional case series, prospective, randomized, masked, controlled clinical trial. METHODS: Setting: Meir Medical Center, Kfar-Saba, Israel. STUDY POPULATION: Adults with uncontrolled primary open angle or pseudoexfoliation glaucoma randomized into 2 groups. INTERVENTION: The controls underwent conventional SLT with 100 spots delivered using a gonioscopy lens for 360 degrees of the trabecular meshwork. The study group underwent irradiation using the same parameters with the laser applications administered on the perilimbal sclera. Study visits: 1 hour, 1, 7, 30, 60, 180, and 365 days postprocedure. MAIN OUTCOME MEASURES: Intraocular pressure (IOP) and side effects. RESULTS: Thirty adults were randomized into 2 groups. The mean (±SD) pretreatment IOP was 20.21±3.19 mm Hg for the study group (n=14) and 21.14±2.98 mm Hg for the controls (n=14; P =0.43), dropping to 15.50±3.77 and 15.00±4.08 mm Hg (P =0.74) after 6 months and to 16.00±3.31 and 14.00±2.45 mm Hg (P =0.22) after 12 months. The average IOP reduction after 6 and 12 months was 23.4% and 20.83% for the study group and 27.1% and 33.77% for the controls (P=0.528). Success (a decrease of ≥15% at 6 months with no additional medications, laser, or glaucoma surgery) was achieved in 12 (85.7%) study patients and 9 (69.2%) controls (P=0.385). Complications were mild and transient (n=30), although significantly higher in the controls (n=15; P <0.0001). CONCLUSIONS: SLT applied directly to the perilimbal sclera may be as efficacious as the conventional procedure for 1 year.

About this research paper

What this paper is about

PURPOSE OF THE STUDY: The purpose of the study was to investigate results of selective laser trabeculoplasty (SLT) performed directly on the sclera without a gonioscopy lens. DESIGN: Interventional case series, prospective, randomized, masked, controlled clinical trial. METHODS: Setting: Meir Medical Center, Kfar-Saba, Israel. STUDY POPULATION: Adults with uncontrolled primary open angle or pseudoexfoliation glaucoma randomized into 2 groups. INTERVENTION: The controls underwent conventional SLT with 100 spots delivered using a gonioscopy lens for 360 degrees of the trabecular meshwork. The study group underwent irradiation using the same parameters with the laser applications administered on the perilimbal sclera. Study visits: 1 hour, 1, 7, 30, 60, 180, and 365 days postprocedure. MAIN OUTCOME MEASURES: Intraocular pressure (IOP) and side effects. RESULTS: Thirty adults were randomized into 2 groups. The mean (±SD) pretreatment IOP was 20.21±3.19 mm Hg for the study group (n=14) and 21.14±2.98 mm Hg for the controls (n=14; P =0.43), dropping to 15.50±3.77 and 15.00±4.08 mm Hg (P =0.74) after 6 months and to 16.00±3.31 and 14.00±2.45 mm Hg (P =0.22) after 12 months. The average IOP reduction after 6 and 12 months was 23.4% and 20.83% for the study group and 27.1% and 33.77% for the controls (P=0.528). Success (a decrease of ≥15% at 6 months with no additional medications, laser, or glaucoma surgery) was achieved in 12 (85.7%) study patients and 9 (69.2%) controls (P=0.385). Complications were mild and transient (n=30), although significantly higher in the controls (n=15; P <0.0001). CONCLUSIONS: SLT applied directly to the perilimbal sclera may be as efficacious as the conventional procedure for 1 year.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE OF THE STUDY: The purpose of the study was to investigate results of selective laser trabeculoplasty (SLT) performed directly on the sclera without a gonioscopy lens. DESIGN: Interventional case series, prospective, randomized, masked, controlled clinical trial. METHODS: Setting: Meir Medical Center, Kfar-Saba, Israel. STUDY POPULATION: Adults with uncontrolled primary open angle or pseudoexfoliation glaucoma randomized into 2 groups. INTERVENTION: The controls underwent conventional SLT with 100 spots delivered using a gonioscopy lens for 360 degrees of the trabecular meshwork. The study group underwent irradiation using the same parameters with the laser applications administered on the perilimbal sclera. Study visits: 1 hour, 1, 7, 30, 60, 180, and 365 days postprocedure. MAIN OUTCOME MEASURES: Intraocular pressure (IOP) and side effects. RESULTS: Thirty adults were randomized into 2 groups. The mean (±SD) pretreatment IOP was 20.21±3.19 mm Hg for the study group (n=14) and 21.14±2.98 mm Hg for the controls (n=14; P =0.43), dropping to 15.50±3.77 and 15.00±4.08 mm Hg (P =0.74) after 6 months and to 16.00±3.31 and 14.00±2.45 mm Hg (P =0.22) after 12 months. The average IOP reduction after 6 and 12 months was 23.4% and 20.83% for the study group and 27.1% and 33.77% for the controls (P=0.528). Success (a decrease of ≥15% at 6 months with no additional medications, laser, or glaucoma surgery) was achieved in 12 (85.7%) study patients and 9 (69.2%) controls (P=0.385). Complications were mild and transient (n=30), although significantly higher in the controls (n=15; P <0.0001). CONCLUSIONS: SLT applied directly to the perilimbal sclera may be as efficacious as the conventional procedure for 1 year.

Key concepts: Medicine, Gonioscopy, Glaucoma, Intraocular pressure, Ophthalmology, Sclera, Trabecular meshwork, Randomized controlled trial

Related papers

Back to paper searchBrowse research topicsOriginal source
Transscleral Selective Laser Trabeculoplasty Without a Gonioscopy Lens — Research Paper | ScholarLens