2016•International Transactions on Electrical Energy SystemsOpen access

Calculation of losses and ampacity derating in medium-voltage cables under harmonic load currents using finite element method

Masoumeh Rasoulpoor, Mohammad Mirzaie, Seyyed Mehdi Mirimani

Open full text 6 citations

Abstract

This paper investigates the influence of metallic sheaths on alternating current (AC) losses and ampacity of power cables. The AC losses are expressed as AC/direct current (DC) resistance in power cables, which is the main factor in loss computations. With regard to the importance of harmonic contents of the currents, a comprehensive study is performed on AC/DC resistance of medium-voltage cables in the presence of harmonics. Different harmonic frequencies include triple and nontriple orders are considered. A derating factor is proposed on the basis of cable constructions. Two types of sheathed and unsheathed medium-voltage power cables are considered. Also for metallic sheathed cables, 2 types of sheath grounding are investigated. It is shown that single-point bonding and both-ends bonding of sheaths have different effects on cable ampacity in harmonic frequencies. Moreover, different conductor cross sections and distances between cables are considered, and their effects on AC/DC resistance and ampacity derating are assessed. It is shown that these factors have important effects on AC/DC resistance and thus power cable losses. Furthermore, all cases are investigated in both flat and trefoil formations that are the most popular formations in power cables. To achieve precise results, we performed this study on the basis of finite element simulation, which is an exact way to cable losses computations in each configuration.

Open-access reader

About this research paper

What this paper is about

This paper investigates the influence of metallic sheaths on alternating current (AC) losses and ampacity of power cables. The AC losses are expressed as AC/direct current (DC) resistance in power cables, which is the main factor in loss computations. With regard to the importance of harmonic contents of the currents, a comprehensive study is performed on AC/DC resistance of medium-voltage cables in the presence of harmonics. Different harmonic frequencies include triple and nontriple orders are considered. A derating factor is proposed on the basis of cable constructions. Two types of sheathed and unsheathed medium-voltage power cables are considered. Also for metallic sheathed cables, 2 types of sheath grounding are investigated. It is shown that single-point bonding and both-ends bonding of sheaths have different effects on cable ampacity in harmonic frequencies. Moreover, different conductor cross sections and distances between cables are considered, and their effects on AC/DC resistance and ampacity derating are assessed. It is shown that these factors have important effects on AC/DC resistance and thus power cable losses. Furthermore, all cases are investigated in both flat and trefoil formations that are the most popular formations in power cables. To achieve precise results, we performed this study on the basis of finite element simulation, which is an exact way to cable losses computations in each configuration.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper investigates the influence of metallic sheaths on alternating current (AC) losses and ampacity of power cables. The AC losses are expressed as AC/direct current (DC) resistance in power cables, which is the main factor in loss computations. With regard to the importance of harmonic contents of the currents, a comprehensive study is performed on AC/DC resistance of medium-voltage cables in the presence of harmonics. Different harmonic frequencies include triple and nontriple orders are considered. A derating factor is proposed on the basis of cable constructions. Two types of sheathed and unsheathed medium-voltage power cables are considered. Also for metallic sheathed cables, 2 types of sheath grounding are investigated. It is shown that single-point bonding and both-ends bonding of sheaths have different effects on cable ampacity in harmonic frequencies. Moreover, different conductor cross sections and distances between cables are considered, and their effects on AC/DC resistance and ampacity derating are assessed. It is shown that these factors have important effects on AC/DC resistance and thus power cable losses. Furthermore, all cases are investigated in both flat and trefoil formations that are the most popular formations in power cables. To achieve precise results, we performed this study on the basis of finite element simulation, which is an exact way to cable losses computations in each configuration.

Key concepts: Derating, Ampacity, Power cable, Harmonic, Harmonics, Electrical engineering, Voltage, Finite element method

Related papers

Back to paper searchBrowse research topicsOriginal source
Calculation of losses and ampacity derating in medium-voltage cables under harmonic load currents using finite element method — Research Paper | ScholarLens