2008•Japanese Journal of Health PhysicsOpen access

Radon Anomalies Prior to Earthquakes (II)-Atmospheric Radon Anomaly Observed before the Hyogoken-Nanbu Earthquake-

Tetsuo Ishikawa, Yumi Yasuoka, Hiroyuki Nagahama, Yusuke Kawada, Yasutaka Omori, Shinji Tokonami, Masaki Shinogi

Open full text 4 citations

Abstract

Before the 1995 Hyogoken-Nanbu earthquake, various geochemical precursors were observed in the aftershock area: chloride ion concentration, groundwater discharge rate, groundwater radon concentration and so on.Kobe Pharmaceutical University (KPU) is located about 25 km northeast from the epicenter and within the aftershock area.Atmospheric radon concentration had been continuously measured from 1984 at KPU, using a flow-type ionization chamber.The radon concentration data were analyzed using the smoothed residual values which represent the daily minimum of radon concentration with the exclusion of normalized seasonal variation.The radon concentration (smoothed residual values) demonstrated an upward trend about two months before the Hyogoken-Nanbu earthquake.The trend can be well fitted to a log-periodic model related to earthquake fault dynamics.As a result of model fitting, a critical point was calculated to be between 13 and 27 January 1995, which was in good agreement with the occurrence date of earthquake (17 January 1995).The mechanism of radon anomaly before earthquakes is not fully understood.However, it might be possible to detect atmospheric radon anomaly as a precursor before a large earthquake, if (1) the measurement is conducted near the earthquake fault, (2) the monitoring station is located on granite (radon-rich) areas, and (3) the measurement is conducted for more than several years before the earthquake to obtain background data.

Open-access reader

About this research paper

What this paper is about

Before the 1995 Hyogoken-Nanbu earthquake, various geochemical precursors were observed in the aftershock area: chloride ion concentration, groundwater discharge rate, groundwater radon concentration and so on.Kobe Pharmaceutical University (KPU) is located about 25 km northeast from the epicenter and within the aftershock area.Atmospheric radon concentration had been continuously measured from 1984 at KPU, using a flow-type ionization chamber.The radon concentration data were analyzed using the smoothed residual values which represent the daily minimum of radon concentration with the exclusion of normalized seasonal variation.The radon concentration (smoothed residual values) demonstrated an upward trend about two months before the Hyogoken-Nanbu earthquake.The trend can be well fitted to a log-periodic model related to earthquake fault dynamics.As a result of model fitting, a critical point was calculated to be between 13 and 27 January 1995, which was in good agreement with the occurrence date of earthquake (17 January 1995).The mechanism of radon anomaly before earthquakes is not fully understood.However, it might be possible to detect atmospheric radon anomaly as a precursor before a large earthquake, if (1) the measurement is conducted near the earthquake fault, (2) the monitoring station is located on granite (radon-rich) areas, and (3) the measurement is conducted for more than several years before the earthquake to obtain background data.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Before the 1995 Hyogoken-Nanbu earthquake, various geochemical precursors were observed in the aftershock area: chloride ion concentration, groundwater discharge rate, groundwater radon concentration and so on.Kobe Pharmaceutical University (KPU) is located about 25 km northeast from the epicenter and within the aftershock area.Atmospheric radon concentration had been continuously measured from 1984 at KPU, using a flow-type ionization chamber.The radon concentration data were analyzed using the smoothed residual values which represent the daily minimum of radon concentration with the exclusion of normalized seasonal variation.The radon concentration (smoothed residual values) demonstrated an upward trend about two months before the Hyogoken-Nanbu earthquake.The trend can be well fitted to a log-periodic model related to earthquake fault dynamics.As a result of model fitting, a critical point was calculated to be between 13 and 27 January 1995, which was in good agreement with the occurrence date of earthquake (17 January 1995).The mechanism of radon anomaly before earthquakes is not fully understood.However, it might be possible to detect atmospheric radon anomaly as a precursor before a large earthquake, if (1) the measurement is conducted near the earthquake fault, (2) the monitoring station is located on granite (radon-rich) areas, and (3) the measurement is conducted for more than several years before the earthquake to obtain background data.

Key concepts: Radon, Aftershock, Epicenter, Geology, Seismology, Anomaly (physics), Earthquake prediction, Fault (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Radon Anomalies Prior to Earthquakes (II)-Atmospheric Radon Anomaly Observed before the Hyogoken-Nanbu Earthquake- — Research Paper | ScholarLens