2016•Journal of Bone and Joint SurgeryRequires access

Repairing the Capsule to the Transferred Coracoid Preserves External Rotation in the Modified Latarjet Procedure

Yoshiaki Itoigawa, Alexander W. Hooke, John W. Sperling, Scott P. Steinmann, Kristin Daigle Zhao, Nobuyuki Yamamoto, Eiji Itoi, Kai‐Nan An

Open publisher page 31 citations

Abstract

BACKGROUND: It is not clear whether the anterior capsule should be repaired to the coracoid process or to the native glenoid during the modified Latarjet procedure. We investigated joint stability and range of motion of the shoulder after the modified Latarjet procedure with both of these methods of capsular repair. METHODS: Eighteen fresh-frozen cadaveric shoulders were used. After a Bankart lesion and 6-mm glenoid defect were created, the coracoid process was transferred to the glenoid and fixed with screws. The anterior capsule was repaired either to the coracoid process (coracoid group) or to the native glenoid (glenoid group). The ranges of internal and external axial rotation were measured with the arm at 0° and 60° of glenohumeral abduction. The range of motion was measured with a constant torque of 200 N-mm. Joint stability was measured using a custom stability testing device. The stability ratio in the anterior-posterior direction was measured with the arm at maximal external rotation and neutral rotation. RESULTS: The range of external rotation was greater at both 0° and 60° of abduction in the coracoid group compared with the glenoid group (p < 0.05). The range of internal rotation was not significantly different between groups. The end-range stability ratio was not significantly different between groups, but the mid-range stability ratio was significantly greater in the glenoid group. CONCLUSIONS: Because the difference in the mid-range stability may not be clinically relevant, we recommend repairing the capsule to the coracoid, as that preserves the range of motion in external rotation. CLINICAL RELEVANCE: Repairing the capsule to the transferred coracoid during the modified Latarjet procedure appears to be beneficial to avoid the limited range of motion in external rotation, but the direct contact of the humeral head and the transferred coracoid might confer a risk of osteoarthritis. Long-term consequences in the clinical setting need to be clarified.

About this research paper

What this paper is about

BACKGROUND: It is not clear whether the anterior capsule should be repaired to the coracoid process or to the native glenoid during the modified Latarjet procedure. We investigated joint stability and range of motion of the shoulder after the modified Latarjet procedure with both of these methods of capsular repair. METHODS: Eighteen fresh-frozen cadaveric shoulders were used. After a Bankart lesion and 6-mm glenoid defect were created, the coracoid process was transferred to the glenoid and fixed with screws. The anterior capsule was repaired either to the coracoid process (coracoid group) or to the native glenoid (glenoid group). The ranges of internal and external axial rotation were measured with the arm at 0° and 60° of glenohumeral abduction. The range of motion was measured with a constant torque of 200 N-mm. Joint stability was measured using a custom stability testing device. The stability ratio in the anterior-posterior direction was measured with the arm at maximal external rotation and neutral rotation. RESULTS: The range of external rotation was greater at both 0° and 60° of abduction in the coracoid group compared with the glenoid group (p < 0.05). The range of internal rotation was not significantly different between groups. The end-range stability ratio was not significantly different between groups, but the mid-range stability ratio was significantly greater in the glenoid group. CONCLUSIONS: Because the difference in the mid-range stability may not be clinically relevant, we recommend repairing the capsule to the coracoid, as that preserves the range of motion in external rotation. CLINICAL RELEVANCE: Repairing the capsule to the transferred coracoid during the modified Latarjet procedure appears to be beneficial to avoid the limited range of motion in external rotation, but the direct contact of the humeral head and the transferred coracoid might confer a risk of osteoarthritis. Long-term consequences in the clinical setting need to be clarified.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: It is not clear whether the anterior capsule should be repaired to the coracoid process or to the native glenoid during the modified Latarjet procedure. We investigated joint stability and range of motion of the shoulder after the modified Latarjet procedure with both of these methods of capsular repair. METHODS: Eighteen fresh-frozen cadaveric shoulders were used. After a Bankart lesion and 6-mm glenoid defect were created, the coracoid process was transferred to the glenoid and fixed with screws. The anterior capsule was repaired either to the coracoid process (coracoid group) or to the native glenoid (glenoid group). The ranges of internal and external axial rotation were measured with the arm at 0° and 60° of glenohumeral abduction. The range of motion was measured with a constant torque of 200 N-mm. Joint stability was measured using a custom stability testing device. The stability ratio in the anterior-posterior direction was measured with the arm at maximal external rotation and neutral rotation. RESULTS: The range of external rotation was greater at both 0° and 60° of abduction in the coracoid group compared with the glenoid group (p < 0.05). The range of internal rotation was not significantly different between groups. The end-range stability ratio was not significantly different between groups, but the mid-range stability ratio was significantly greater in the glenoid group. CONCLUSIONS: Because the difference in the mid-range stability may not be clinically relevant, we recommend repairing the capsule to the coracoid, as that preserves the range of motion in external rotation. CLINICAL RELEVANCE: Repairing the capsule to the transferred coracoid during the modified Latarjet procedure appears to be beneficial to avoid the limited range of motion in external rotation, but the direct contact of the humeral head and the transferred coracoid might confer a risk of osteoarthritis. Long-term consequences in the clinical setting need to be clarified.

Key concepts: Latarjet procedure, Coracoid, Capsule, Rotation (mathematics), Anatomy, Geology, Geometry, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Repairing the Capsule to the Transferred Coracoid Preserves External Rotation in the Modified Latarjet Procedure — Research Paper | ScholarLens