Will Ultrasound Performed with the Rich-Mar AutoSound™ Be as Effective at Increasing Tissue Temperature as Ultrasound Performed with a Traditional Machine?

Heather Diane Black

Open publisher page 0 citations

Abstract

STUDY DESIGN: Randomized crossover experiment. OBJECTIVE: To determine whether the Rich-Mar AutoSound™ would be as effective as traditional ultrasound at increasing the temperature of the triceps surae muscle during a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment. BACKGROUND: The AutoSound™ is a hands-free ultrasound device that is strapped on the body and left for the duration of the ultrasound treatment. It requires no clinician during the actual ultrasound treatment, thus freeing the clinician to perform other tasks and reducing clinician error during treatments. METHODS: 16 healthy subjects (6 males, 10 females, age = 22 ± 1.6 yrs, height = 173.2 ± 8.4 cm, weight = 72.5 ± 11.3 kg, triceps surae subcutaneous fat thickness = 0.85 ± 0.37 cm) received a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment over their left triceps surae muscle with both the AutoSound™ and traditional ultrasound (via the TheraHammer™) with 24 hours between treatments. Temperatures were measured every 30 seconds during the ultrasound treatments by way of a thermistor, approximately 2.25 cm deep in the triceps surae. RESULTS: The AutoSound™ was not effective at increasing the temperature of the triceps surae muscle, as temperature decreased 0.16°C during treatment (p = 0.334). On average, the AutoSound™ caused intramuscular temperature to decrease at a rate of 0.016 ± 0.001°C per min. Traditional ultrasound performed using the TheraHammer™ had a total temperature increase of 0.41°C. Rate of temperature increase during traditional ultrasound was 0.025 ± 0.003°C per min (p < 0.0001). CONCLUSION: The AutoSound™ is not as effective at increasing muscle temperature as traditional ultrasound during a 10-min, 1 MHz, 1.0 W/cm2 treatment. However, neither the AutoSound™ nor traditional ultrasound was very effective at increasing the temperature of the triceps surae muscle during the treatment time.

About this research paper

What this paper is about

STUDY DESIGN: Randomized crossover experiment. OBJECTIVE: To determine whether the Rich-Mar AutoSound™ would be as effective as traditional ultrasound at increasing the temperature of the triceps surae muscle during a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment. BACKGROUND: The AutoSound™ is a hands-free ultrasound device that is strapped on the body and left for the duration of the ultrasound treatment. It requires no clinician during the actual ultrasound treatment, thus freeing the clinician to perform other tasks and reducing clinician error during treatments. METHODS: 16 healthy subjects (6 males, 10 females, age = 22 ± 1.6 yrs, height = 173.2 ± 8.4 cm, weight = 72.5 ± 11.3 kg, triceps surae subcutaneous fat thickness = 0.85 ± 0.37 cm) received a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment over their left triceps surae muscle with both the AutoSound™ and traditional ultrasound (via the TheraHammer™) with 24 hours between treatments. Temperatures were measured every 30 seconds during the ultrasound treatments by way of a thermistor, approximately 2.25 cm deep in the triceps surae. RESULTS: The AutoSound™ was not effective at increasing the temperature of the triceps surae muscle, as temperature decreased 0.16°C during treatment (p = 0.334). On average, the AutoSound™ caused intramuscular temperature to decrease at a rate of 0.016 ± 0.001°C per min. Traditional ultrasound performed using the TheraHammer™ had a total temperature increase of 0.41°C. Rate of temperature increase during traditional ultrasound was 0.025 ± 0.003°C per min (p < 0.0001). CONCLUSION: The AutoSound™ is not as effective at increasing muscle temperature as traditional ultrasound during a 10-min, 1 MHz, 1.0 W/cm2 treatment. However, neither the AutoSound™ nor traditional ultrasound was very effective at increasing the temperature of the triceps surae muscle during the treatment time.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY DESIGN: Randomized crossover experiment. OBJECTIVE: To determine whether the Rich-Mar AutoSound™ would be as effective as traditional ultrasound at increasing the temperature of the triceps surae muscle during a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment. BACKGROUND: The AutoSound™ is a hands-free ultrasound device that is strapped on the body and left for the duration of the ultrasound treatment. It requires no clinician during the actual ultrasound treatment, thus freeing the clinician to perform other tasks and reducing clinician error during treatments. METHODS: 16 healthy subjects (6 males, 10 females, age = 22 ± 1.6 yrs, height = 173.2 ± 8.4 cm, weight = 72.5 ± 11.3 kg, triceps surae subcutaneous fat thickness = 0.85 ± 0.37 cm) received a 10-min, 1 MHz, 1.0 W/cm2 ultrasound treatment over their left triceps surae muscle with both the AutoSound™ and traditional ultrasound (via the TheraHammer™) with 24 hours between treatments. Temperatures were measured every 30 seconds during the ultrasound treatments by way of a thermistor, approximately 2.25 cm deep in the triceps surae. RESULTS: The AutoSound™ was not effective at increasing the temperature of the triceps surae muscle, as temperature decreased 0.16°C during treatment (p = 0.334). On average, the AutoSound™ caused intramuscular temperature to decrease at a rate of 0.016 ± 0.001°C per min. Traditional ultrasound performed using the TheraHammer™ had a total temperature increase of 0.41°C. Rate of temperature increase during traditional ultrasound was 0.025 ± 0.003°C per min (p < 0.0001). CONCLUSION: The AutoSound™ is not as effective at increasing muscle temperature as traditional ultrasound during a 10-min, 1 MHz, 1.0 W/cm2 treatment. However, neither the AutoSound™ nor traditional ultrasound was very effective at increasing the temperature of the triceps surae muscle during the treatment time.

Key concepts: Ultrasound, Triceps surae muscle, Medicine, Therapeutic ultrasound, Crossover study, Nuclear medicine, Anatomy, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Will Ultrasound Performed with the Rich-Mar AutoSound™ Be as Effective at Increasing Tissue Temperature as Ultrasound Performed with a Traditional Machine? — Research Paper | ScholarLens