2016•IET Generation Transmission & DistributionRequires access

Adaptive busbar differential relaying scheme during saturation period of current transformers based on alienation concept

Ragab Abd Allah

Open publisher page 25 citations

Abstract

This study presents an advanced technique provided with adaptive differential relay characteristics for avoiding current transformer (CT) saturation effects. The proposed technique uses the alienation and differential protection principles to make adaptive logic; if no CT saturation is detected, the differential principle alone is capable of tripping the busbar. If CT saturation is detected, both the alienation and differential principles must pickup in order to trip. The alienation coefficient is useful in CT saturation detection, evaluation of CT saturation degree and adapting the differential relay characteristics during saturation period of CTs to avoid false operation in the event of external faults. The differential current and alienation coefficient are calculated from two terminal currents of the busbar. The proposed protective scheme has several attractive features, including the simplicity of on‐line implementation, not affected by the remanent flux in the CT core, and it is independent of the CT parameters/characteristics and secondary burden. A real 19.57 kV busbar is simulated using Alternate Transients Program/Electro‐Magnetic Transient Program and MATLAB packages to examine the suggested scheme under different types of faults. Under normal operating conditions and external faults, the scheme remains stable and it operates only for the case of internal faults. Moreover, it is unaffected by CT saturation.

About this research paper

What this paper is about

This study presents an advanced technique provided with adaptive differential relay characteristics for avoiding current transformer (CT) saturation effects. The proposed technique uses the alienation and differential protection principles to make adaptive logic; if no CT saturation is detected, the differential principle alone is capable of tripping the busbar. If CT saturation is detected, both the alienation and differential principles must pickup in order to trip. The alienation coefficient is useful in CT saturation detection, evaluation of CT saturation degree and adapting the differential relay characteristics during saturation period of CTs to avoid false operation in the event of external faults. The differential current and alienation coefficient are calculated from two terminal currents of the busbar. The proposed protective scheme has several attractive features, including the simplicity of on‐line implementation, not affected by the remanent flux in the CT core, and it is independent of the CT parameters/characteristics and secondary burden. A real 19.57 kV busbar is simulated using Alternate Transients Program/Electro‐Magnetic Transient Program and MATLAB packages to examine the suggested scheme under different types of faults. Under normal operating conditions and external faults, the scheme remains stable and it operates only for the case of internal faults. Moreover, it is unaffected by CT saturation.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study presents an advanced technique provided with adaptive differential relay characteristics for avoiding current transformer (CT) saturation effects. The proposed technique uses the alienation and differential protection principles to make adaptive logic; if no CT saturation is detected, the differential principle alone is capable of tripping the busbar. If CT saturation is detected, both the alienation and differential principles must pickup in order to trip. The alienation coefficient is useful in CT saturation detection, evaluation of CT saturation degree and adapting the differential relay characteristics during saturation period of CTs to avoid false operation in the event of external faults. The differential current and alienation coefficient are calculated from two terminal currents of the busbar. The proposed protective scheme has several attractive features, including the simplicity of on‐line implementation, not affected by the remanent flux in the CT core, and it is independent of the CT parameters/characteristics and secondary burden. A real 19.57 kV busbar is simulated using Alternate Transients Program/Electro‐Magnetic Transient Program and MATLAB packages to examine the suggested scheme under different types of faults. Under normal operating conditions and external faults, the scheme remains stable and it operates only for the case of internal faults. Moreover, it is unaffected by CT saturation.

Key concepts: Busbar, Current transformer, Transformer, Alienation, Saturation (graph theory), Electronic engineering, Electrical engineering, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Adaptive busbar differential relaying scheme during saturation period of current transformers based on alienation concept — Research Paper | ScholarLens